Owner`s manual

gure 12
gure 13
gure 14
gure 11
16
Installation
Installing the Remote Monitor
Having determined the location of both
the central vacuum unit and the Remote
System Monitor, run low voltage wiring to
connect the Monitor to the central vacuum
power unit.
Installing the Remote Monitor
1. Insert the low voltage wire into the
mounting box through one of the
designated openings, and fasten within
the wall at the determined location
(fi gure 11).
2. Having stripped the exterior casing of the
four-stranded wire, strip 0,5 cm (¼") of
each color wire.
3. Connect wires to the module connector.
Insert each of the 4 color wires in the
corresponding color-coded inlet on the
connector. To do so, loosen the screw on
the side of each inlet, insert the wire, and
tighten screw to ensure a tight connection.
Repeat for each of the remaining 3 wires
(fi gure 12).
4. Insert the connector to the electronic
module and ensure it holds in place
(fi gure 13).
5. Screw the electronic module to the
mounting box, with the two screws
provided (fi gure 14).
6. Complete with the “Decora”  nishing
plate.
(Optional — GX series only)
A. Red
B. Black
C. Green
D. Yellow