Datasheet

www.cynergy3.com
© 2018 Cynergy3 Components, All Rights Reserved. Specifications are subject to change without prior notice. Cynergy3 Components and the Cynergy3 Components logo are trademarks of Cynergy3 Components Limited.
ISO9001
C ERTI F I E D
DA(UL) Series
Cynergy3 Components Ltd.
7 Cobham Road
Ferndown Industrial Estate
Wimborne, Dorset BH21 7PE
DA(UL) 2019
Telephone +44 (0) 1202 897969
Email:sales@cynergy3.com
Recently approved by UL, very high
isolation voltages (up to 10kV) are
achieved through the use of high vacuum
reed switches with either Rhodium or
Tungsten contacts and make these relays
suitable for high reliability applications,
such as cardiac defibrillators, test
equipment and high voltage power
supplies.
PCB or Panel Mount, via Nylon studs,
versions are available.
A choice of 5kV, 7.5kV and 10kV isolation
voltages is available
The Rhodium contact relays have low
contact resistance, while the Tungsten
contact relays can switch higher voltages.
Connection options, for the HV, include
PCB, solder turret(wire wrap), flying lead
and 0.25” spade terminals.
PCB or Panel Mount
Excellent AC characteristics
Choice of 10kV, 7.5kV or 5kV Isolation
Low Contact Resistance
HV connections via Flying Leads, Solder Turret
(wire wrap), or 1/4” Spade Terminals
Switching Power Max. W 50 50 50 50 50 50
9 9 9 9 9 9
Lifetime operations dry switching 10 10 10 10 10 10
10 13 10 13 10 13
Insulation Resistance Wmin (typical) 10 (10 ) 10 (10 ) 10 (10 )
Carry Current Max A DC or AC peak 4 3 4 3 4 3
Capacitance across pF coil to screen <0.2 <0.2 <0.2 <0.2 <0.2 <0.2
6 6 6 6 6 6
50W switching 10 10 10 10 10 10
10 13
to all terminals Wmin (typical) 10 (10 )
Operating Temp range ºC -20 to +70
Isolation contact/coil kV 17
contacts grounded
Contact Material Rhodium Tungsten Rhodium Tungsten Rhodium Tungsten
Contact Specification Unit Condition 10kV 7.5kV 5kV
Isolation across contacts kV DC or AC peak 10 10 7.5 7.5 5 5
Switching Voltage Max. V DC or AC peak 1000 7000 1000 5000 1000 3500
Contact Form N/O (normally open)
Switching Current Max. A DC or AC peak 3 2 3 2 3 2
Contact Resistance mW max (typical) 50 (15) 250(100) 50 (15) 250(100) 50 (15) 250(100)
Coil Specification 5V 12V 24V
Must Operate Voltage V DC 3.7 9 20
Must Release Voltage V DC 0.5 1.25 4
Operate Time ms diode fitted 3.0 3.0 3.0
Release Time ms diode fitted 2.0 2.0 2.0
Note. The operate / release voltage and coil resistance will change at a rate of 0.4% per degree C. Values are stated at room temperature (20 degrees C)
Resistance W 28 150 780
Relay Specification
Insulation resistance contact
Environmental
Part Numbering System
D A T 7 12 10 F U
Reed Switch Size
Contact Form A=n/o
Moulding Ref. No.
R=Rhodium,
T=Tungsten
Contact Material
05=5Vdc, 12=12Vdc,
24=24Vdc
Coil Voltage
75=7.5kV
05=5kV
10=10kV
Isolation between
Contacts
P=Panel mount with wire wrap
terminals
T=PCB mount & coil connection with
stud fixing & wire wrap HV
connection
Mounting or Connection Style
S=PCB mount & coil connection with
stud fixing & 1/4” spade HV
connection
F=PCB mount & coil connection with
Flying lead HV connection
No suffix indicates PCB mount
*Consult factory for UL ratings
U” indicates UL approved
UL Approved*, Normally Open, High Voltage Relays - 10kV, 7.5kV & 5kV
Made in the UK
These products have been UL approved for use as per pollution degree 2 classification.
If you require further information as to how this my affect product usage, please contact sales@cynergy3.com.