Datasheet
Very high isolation voltages, up to 15kV, are
achieved through the use of high vacuum reed
switches with either Rhodium or Tungsten contacts
and make these relays suitable for high reliability
applications such as cardiac defibrillators, test
equipment and high voltage power supplies.
The Rhodium contacts have low contact resistance
while the Tungsten contacts can switch higher
voltages.
Printed Circuit Board (PCB) or Panel mount, via
nylon studs, versions are available.
Connection options include PCB, solder turret tag,
flying lead and Faston* style Spade Terminals.
Available as Form A (SPNO) or Form B (SPNC)
contact configurations.
15kV Isolation
Low Contact Resistance
High Power Switching
PCB or Panel Mount
Flying Lead, Solder and Faston* Style Spade
Terminal Options
Contact Units Conditions 10kV Form A 10kV Form B 15kV Form A
Contact Materials
Rhodium Tungsten Rhodium Tungsten Tungsten
Isolation Across Contacts kV DC or AC peak 10 10 10 10 15
Max. Switching Power W 50 50 50 50 50
Max. Switching Voltage V DC or AC peak 1000 7000 1000 7000 10000
Max. Switching Current A DC or AC peak 3 2 3 2 2
Max. Current Carry A DC or AC peak 4 3 4 3 2
Capacitance Across Contacts pF Coil/Screen Grounded <0.2 <0.2 <0.2 <0.2 <0.2
Lifetime Operations Dry Switching 10
9
10
9
10
9
10
9
10
9
Lifetime Operations 50W Switching 10
6
10
6
10
6
10
6
10
8
Contact Resistance mOhms Maximum (Typical) 50 (15) 250 (100) 50 (15) 250 (100) 250 (100)
Insulation Resistance Ohms Minimum (Typical) 10
10
(10
13
) 10
10
(10
13
) 10
10
(10
13
) 10
10
(10
13
) 10
10
(10
13
)
Competitive part number cross-reference available at: www.cynergy3.com
ISO
9001
C E R T I F I E D
D series
high voltage reed relays
15kV, 50W
TM
TM
Coil at 20°C 5V 12V 24V 5V 12V 24V 5V 12V 24V
Must Operate V DC 3.7 9 20 3.7 9 20 3.7 9 20
Must Release V DC 0.5 1.25 4 0.5 1.25 4 0.5 1.25 4
Operate Time ms Diode Fitted 3.0 3.0 3.0 2.0 2.0 2.0 3.0 3.0 3.0
Release Time ms Diode Fitted 2.0 2.0 2.0 3.0 3.0 3.0 2.0 2.0 2.0
Resistance Ohms 28 150 780 38 240 925 16 95 350
Construction
Isolation Contact to Coil kV DC or AC peak 17 17 17
Insulation Resistance Contact
to All Other Terminals Ohms Minimum (Typical) 10
10
(10
13
) 10
10
(10
13
) 10
10
(10
13
)
Environmental
Operating Temperature Range °C -20 to +70 -20 to +70 -20 to +70
Weight Version
Standard Panel Spade Flying Lead
Form A gm 23 28 29 38
Form B gm 31 36 37 46