Datasheet

Table Of Contents
www.cynergy3.com
© 2018 Cynergy3 Components, All Rights Reserved. Specifications are subject to change without prior notice. Cynergy3 Components and the Cynergy3 Components logo are trademarks of Cynergy3 Components Limited.
ISO9001
C ERTI F I E D
DB(UL) Series
Cynergy3 Components Ltd.
7 Cobham Road
Ferndown Industrial Estate
Wimborne, Dorset BH21 7PE
DB(UL) 2019
Telephone +44 (0) 1202 897969
Email:sales@cynergy3.com
Recently approved by UL, very high
isolation voltages (up to 10kV) are
achieved through the use of high vacuum
reed switches with either Rhodium or
Tungsten contacts and make these relays
suitable for high reliability applications,
such as cardiac defibrillators, test
equipment and high voltage power
supplies.
A choice of 5kV, 7.5kV and 10kV isolation
voltages is available
The Rhodium contact relays have low
contact resistance, while the Tungsten
contact relays can switch higher voltages,
up to 7000Vdc/ac peak to peak
PCB or Panel Mount, via Nylon studs,
versions are available.
Connection options, for the HV, include
PCB, solder turret(wire wrap), flying lead
and 0.25” spade terminals.
PCB or Panel Mount
Excellent AC characteristics
Low Contact Resistance
HV connections via Flying Leads, Solder Turret
(wire wrap), or 1/4” Spade Terminals
Part Numbering System
D B T 7 12 10 F U
Reed Switch Size
Contact Form B =n/c
Moulding Ref. No.
R= Rhodium
Contact Material
T=Tungsten
Coil Voltage
05=5Vdc, 12=12Vdc,
24=24Vdc
Mounting or Connection Style
No suffix indicates PCB mount
S=PCB mount & coil connection with
stud fixing & 1/4” spade HV
connection
F=PCB mount & coil connection with
Flying lead HV connection
T=PCB mount & coil connection with
stud fixing & wire wrap HV
connection
P=Panel mount with wire wrap
terminals
*Consult factory for UL ratings
U” indicates UL approved
UL Approved* Normally Closed, High Voltage Relays - 10kV, 7.5kV & 5kV
Made in the UK
Choice of 10kV, 7.5kV or 5kV Isolation
Carry Current Max A DC or AC peak 4 3 4 3 4 3
Contact Material Rhodium Tungsten Rhodium Tungsten Rhodium Tungsten
Isolation across contacts kV DC or AC peak 10 10 7.5 7.5 5 5
Must Operate Voltage V DC 3.7 9 20
Operate Time ms diode fitted 2.0 2.0 2.0
Contact Specification Unit Condition 10kV 7.5kV 5kV
Switching Voltage Max. V DC or AC peak 1000 7000 1000 5000 1000 3500
Capacitance across pF coil to screen <0.2 <0.2 <0.2 <0.2 <0.2 <0.2
Contact Form N/C (normally colsed)
Switching Power Max. W 50 50 50 50 50 50
Switching Current Max. A DC or AC peak 3 2 3 2 3 2
contacts grounded
9 9 9 9 9 9
Lifetime operations dry switching 10 10 10 10 10 10
6 6 6 6 6 6
50W switching 10 10 10 10 10 10
Contact Resistance mW max (typical) 50 (15) 250(100) 50 (15) 250(100) 50 (15) 250(100)
10 13 10 13 10 13
Insulation Resistance Wmin (typical) 10 (10 ) 10 (10 ) 10 (10 )
Coil Specification 5V 12V 24V
Must Release Voltage V DC 0.5 1.25 4
Release Time ms diode fitted 3.0 3.0 3.0
Note. The operate / release voltage and coil resistance will change at a rate of 0.4% per degree C. Values are stated at room temperature (20 degrees C)
10 13
to all terminals Wmin (typical) 10 (10 )
Resistance W 38 240 925
Isolation contact/coil kV 17
Environmental
Operating Temp range ºC -20 to +70
Insulation resistance contact
Relay Specification
Isolation between
Contacts
10=10kV
05=5kV
75=7.5kV
These products have been UL approved for use as per pollution degree 2 classification.
If you require further information as to how this may affect product usage, please contact sales@cynergy3.com.

Summary of content (2 pages)