Datasheet
• Non-invasive sensor technology
• Fully electronic, no moving parts
• Automatic viscosity and
temperature compensation
• Pulse or analogue output selectable
• Low pressure drop
• LED indication of no liquid &
of flow rate
Operation
Principle Ultrasonic transit time in-line flow cell
Temp. range (fluid) -10°C to 85°C
Continuous fluid sound Maintains performance regardless of fluid type, temperature
or viscosity for speed measurement fluids with sound speeds
1250 - 1750 m/s
Interface
Connection 8 wires (RED supply +ve, BLACK ground, Blue NPN output, Yellow Data in, White PNP
output, Orange Voltage output, Brown Current output, Green Ground connected internally to black)
Supply - 2 VDC (input current <1 mA @ VDC)84 5 24
Output selectable 1000 pulses/L 0-5Vdc 4-20mA
Performance
Accuracy 3% of readingfor flow rates between Q2 and Q4
Accuracy % of readingfor flow rates between Q1 and Q2 5
R01esolution better than 0.0 L/min
Reverse flow 0- L/min8
Response time Better than 0. s1
This innovative design provides a high accuracy, non-invasive, flow measurement
device at a fraction of the cost of other current non-invasive systems. The unique
measurement technique automatically compensates for viscosity and temperature
variations. The measurement of flow is by ultrasonic transit time in-line cell.
The flow path is designed to minimise pressure drop and, having no moving parts
within, will not clog or jam. The sensor also allows contaminants to pass through
without affecting its performance.
The sensor supplied with pulse and analogue outputsis , which are selectable by
connection wires..
Technical Specifications
Max. flow L/min (Q4) 8
Transitional flow (Q2) 0.4
Min. flow L/min 0.(Q1) 1
Output selectable Pulse Analogue
Cable length (cms)
Output ( = selectable)B
Physical characteristics
Flow tube material Glass filled plastic, Grivory HT V-41 FWA Black 9225
( ved oo )FDA and EU appro for f dstuffs
Flow tube internal diameter mm7
Connection thread 3/8” straight tube
Internal bore of connection mm7
Suitable Pushfit adaptor (to fit ” OD Tube) John Guest Speedfit PI S3/8 0412
Maximum pressure bar10
Case material ABS black, Polylac PA-757
Case integrity Ultrasonically welded, not liquid proof
Connection core, PVC sheathed, 100cm long standard8
Environmental protection IP66
UF 0 1008 B
Ordering Code
Series
Flow range ( = 0 to L/min)88
Ultrasonic Flow Meter UF08B
Cynergy3 Components Ltd.
7 Cobham Road
Ferndown Industrial Estate
Wimborne, Dorset BH21 7PE
UF08B 2016
Telephone +44 (0) 1202 897969
Email:sales@cynergy3.com
ISO
9001
CERTIFIED
© 2016 Cynergy3 Components, All Rights Reserved. Specifications are subject to change without prior notice. Cynergy3 Components and the Cynergy3 Components logo are trademarks of Cynergy3 Components Limited.
www.cynergy3.com