ADC Port
The CYBT-2X30XX-02 includes a Σ-Δ ADC designed for audio and DC measurements. The ADC can measure the voltage on 15
GPIOs (P0, P1, P8-P15, P17, P28, P29, and P37). When used for analog inputs, the GPIOs must be placed in digital input disable
mode to disconnect the digital circuit from the pin and avoid leakage. The internal bandgap reference has ±5% accuracy without
calibration. Calibration and digital correction schemes can be applied to reduce ADC absolute error and improve measurement
accuracy in Direct Current (DC) Mode.
The application can access the ADC through the ADC driver included in the firmware.
The following CYBT-2X30XX-02 module solder pads can be used as ADC inputs:
Pad 3: P29, ADC Input Channel 10
Pad 5: P37, ADC Input Channel 2
Pad 6: P1, ADC Input Channel 28
Pad 7: P0, ADC Input Channel 29
Pad 8: P10, ADC Input Channel 25
Pad 9: P11, ADC Input Channels 24
Pad 10: P13, ADC Input Channel 22
Pad 11: P14, ADC Input Channel 21
Pad 12: P12, ADC Input Channel 23
Pad 14: P9, ADC Input Channels 26
Pad 15: P17, ADC Input Channels 18
Pad 24: P8, ADC Input Channels 27
Pad 24: P15, ADC Input Channels 20
Pad 27: P28, ADC Input Channels 11
GPIO Port
The CYBT-2X30XX-02 has a maximum of 20 GPIOs. All GPIOs support the following:
Programmable pull-up/down of approximately 45 kΩ.
Input disable mode, allowing pins to be left floating or analog signals connected without risk of leakage.
Source/sink 8 mA at 3.3 V and 4 mA at 1.8 V.
P26/P28/P29 can sink/source 16 mA at 3.3 V and 8 mA at 1.8 V.
Most peripheral functions can be assigned to any GPIO using the ModusToolbox Device Configurator. For details on the functions
that are assignable via the ModusToolbox Device Configurator, refer to Table 5.
The following list details the GPIOs that are available on the CYBT-2X30XX-02 module:
P0-P6, P8-P15, P17, P26-P29, and P37