PRELIMINARY
CYBLE-214009-00
Document Number: 002-09714 Rev. ** Page 29 of 40
ITX,-12dBm TX current at –12-dBm setting (PA2) – 13.2 – mA
ITX,-18dBm TX current at –18-dBm setting (PA1) – 12.5 – mA
Iavg_1sec, 0dBm Average current at 1-second BLE
connection interval
– 17.1 – µA TXP: 0 dBm; ±20-ppm
master and slave clock
accuracy.
For empty PDU exchange
Iavg_4sec, 0dBm Average current at 4-second BLE
connection interval
– 6.1 – µA TXP: 0 dBm; ±20-ppm
master and slave clock
accuracy.
For empty PDU exchange
General RF Specifications
FREQ RF operating frequency 2400 – 2482 MHz
CHBW Channel spacing – 2 – MHz
DR On-air data rate – 1000 – kbps
IDLE2TX BLE.IDLE to BLE. TX transition time – 120 140 µs
IDLE2RX BLE.IDLE to BLE. RX transition time – 75 120 µs
RSSI Specifications
RSSI, ACC RSSI accuracy – ±5 – dB
RSSI, RES RSSI resolution – 1 – dB
RSSI, PER RSSI sample period – 6 – µs
Table 53. BLE Subsystem (continued)
Parameter Description Min Typ Max Units
Details/