Table 25. Timer DC Specifications
Parameter Description Min Typ Max Unit Details/Conditions
I
TIM1
Block current consumption at 3 MHz – – 42 µA 16-bit timer
I
TIM2
Block current consumption at 12 MHz – – 130 µA 16-bit timer
I
TIM3
Block current consumption at 48 MHz – – 535 µA 16-bit timer
Table 26. Timer AC Specifications
Parameter Description Min Typ Max Unit Details/Conditions
T
TIMFREQ
Operating frequency F
CLK
–48MHz –
T
CAPWINT
Capture pulse width (internal) 2 × T
CLK
––ns –
T
CAPWEXT
Capture pulse width (external) 2 × T
CLK
––ns –
T
TIMRES
Timer resolution T
CLK
––ns –
T
TENWIDINT
Enable pulse width (internal) 2 × T
CLK
––ns –
T
TENWIDEXT
Enable pulse width (external) 2 × T
CLK
––ns –
T
TIMRESWINT
Reset pulse width (internal) 2 × T
CLK
––ns –
T
TIMRESEXT
Reset pulse width (external) 2 × T
CLK
––ns –
Table 27. Counter DC Specifications
Parameter Description Min Typ Max Unit Details/Conditions
I
CTR1
Block current consumption at 3 MHz – – 42 µA 16-bit counter
I
CTR2
Block current consumption at 12 MHz – – 130 µA 16-bit counter
I
CTR3
Block current consumption at 48 MHz – – 535 µA 16-bit counter
Table 28. Counter AC Specifications
Parameter Description Min Typ Max Unit Details/Conditions
T
CTRFREQ
Operating frequency F
CLK
–48MHz –
T
CTRPWINT
Capture pulse width (internal) 2 × T
CLK
––ns –
T
CTRPWEXT
Capture pulse width (external) 2 × T
CLK
––ns –
T
CTRES
Counter Resolution T
CLK
––ns –
T
CENWIDINT
Enable pulse width (internal) 2 × T
CLK
––ns –
T
CENWIDEXT
Enable pulse width (external) 2 × T
CLK
––ns –
T
CTRRESWINT
Reset pulse width (internal) 2 × T
CLK
––ns –
T
CTRRESWEXT
Reset pulse width (external) 2 × T
CLK
–– ns –
Table 29. PWM DC Specifications
Parameter Description Min Typ Max Unit Details/Conditions
I
PWM1
Block current consumption at 3 MHz – – 42 µA 16-bit PWM
I
PWM2
Block current consumption at 12 MHz – – 130 µA 16-bit PWM
I
PWM3
Block current consumption at 48 MHz – – 535 µA 16-bit PWM