Datasheet

CY8CMBR3002, CY8CMBR3102
CY8CMBR3106S, CY8CMBR3108
CY8CMBR3110, CY8CMBR3116 Datasheet
Document Number: 001-85330 Rev. *G Page 16 of 37
Note If more than one button is activated at the same time, the
Rn becomes equivalent (parallel) to all Rn resistors.
For the circuit represented in Figure 11 to work, GPOs should
be configured in the Active LOW logic, open-drain drive mode.
PWM must be disabled and the CSx-to-GPOx direct drive must
be enabled (that is, GPOs must be configured as
sensor-controlled).
The FSS feature can be enabled so only one button is reported
ON at a time.
System Diagnostics
System Diagnostics is a BIST feature that tests for faulty sensor,
shield, or CMOD conditions at device resets.
If any sensor fails these tests, a 50-ms pulse is sent out on the
corresponding GPO (that is, the pulse is observed on GPOx if
CSx fails the test), and the sensor is disabled.
If the shield fails the tests, a 50-ms pulse is sent out on all GPOs
and all the sensors are disabled.
If CMOD fails the tests, a 50-ms pulse is sent out on all GPOs
and all the sensors are disabled.
System Diagnostics failure pulses are sent within device
boot-up time.
The System Diagnostics status is also updated in the register
map. Therefore, the host can also read test results through the
I
2
C interface.
Sensor C
P
> 45 pF
If the parasitic capacitance of a sensor is more than 45 pF, the
sensor is disabled.
Improper value of CMOD
If the value of CMOD is less than 1 nF or greater than 4 nF, all
sensors are disabled (the recommended value of CMOD is
2.2 nF).
Sensor shorts
System Diagnostics also checks for the following errors:
Sensor shorted to V
ss
Sensor shorted to V
DD
Sensor shorted to another sensor
Sensor shorted to shield