Datasheet
112 PSoC Designer IDE Guide, Document # 001-42655 Rev *B
Debugger
7.3 Connecting to the ICE
You must establish a communication link between the PC and the ICE. This is done by choosing the
appropriate ‘port’. To make the Debugger port selection select the Project > Settings > Debugger
tab.
Figure 7-2. Debugger Project Settings - LPT1
The “ICE connected to:” list shows parallel ports (i.e., LPT1…3) supporting the original PSoC ICE.
The definition of the USB ports are determined by this coding:
USB/yywwTxxx
Where:
yy: Year the ICE was manufactured
ww: Work week the ICE was manufactured
T: Type of USB connection where:
C: ICE Cube
D: USB Adapter/Dongle for a legacy ICE
xxx: Manufacturing sequence number
Once you have set your debugger port, and are connected to your ICE, check the PC to ICE com-
munication link by using the Connect button or by selecting the Debug > Connect/Disconnect