Datasheet
PSoC Designer IDE Guide, Document # 001-42655 Rev *B 33
Chip-Level Editor
RBotMux for a CT Analog Block
To select a RBotMux for a CT Analog Block, follow this procedure. You can use this procedure when
the NMux, PMux, AnalogBus, or CompBus CT Analog Block apply, as well as for ACMux, BMux,
AnalogBus, or CompBus SC Analog Blocks.
1. Click the RBotMux text label on the analog block where your target user module was placed.
Note that the name RBotMux is determined by a specified user module parameter.
Figure 2-15. Setting the Comparator Bus on a Comparator User Module
2. Select an option from the menu.
You see your chosen option displayed next to the RBotMux text label. Your choice option also
appears in the RBotMux field under User Module Parameters (where you can click the drop-
arrow to change your selection).
Row Broadcast
Row Broadcast connections do not apply to CY8C25xxx/26xxx parts. To set Row Broadcast connec-
tions:
1. Click the Row_0_Broadcast (BC0) or Row_1_Broadcast (BC1) horizontal line.
Figure 2-16. Setting the Row_0_Broadcast Line
2. Select an option from the menu.
You see a line connecting to a digital PSoC block or to the other Row Broadcast, depending on
the option you chose.