User manual

CY8C29466, CY8C29566
CY8C29666, CY8C29866
Document Number: 38-12013 Rev. *M Page 35 of 47
12.4.7 AC External Clock Specifications
The following tables list guaranteed maximum and minimum specifications for the voltage and temperature ranges: 4.75V to 5.25V
and -40
°C T
A
85°C, or 3.0V to 3.6V and -40°C T
A
85°C, respectively. Typical parameters apply to 5V and 3.3V at 25°C and
are for design guidance only.
12.4.8 AC Programming Specifications
The following table lists guaranteed maximum and minimum specifications for the voltage and temperature ranges: 4.75V to 5.25V
and -40
°C T
A
85°C, or 3.0V to 3.6V and -40°C T
A
85°C, respectively. Typical parameters apply to 5V and 3.3V at 25°C and
are for design guidance only.
Table 12-25. 5V AC External Clock Specifications
Symbol Description Min Typ Max Unit
F
OSCEXT
Frequency 0.093 24.6 MHz
High Period 20.6
5300 ns
Low Period 20.6
–ns
Power Up IMO to Switch 150
–ms
Table 12-26. 3.3V AC External Clock Specifications
Symbol Description Min Typ Max Unit
F
OSCEXT
Frequency with CPU Clock divide by 1 0.093 12.3 MHz
F
OSCEXT
Frequency with CPU Clock divide by 2 or greater 0.186 24.6 MHz
High Period with CPU Clock divide by 1 41.7
5300 ns
Low Period with CPU Clock divide by 1 41.7
–ns
Power Up IMO to Switch 150
μs
Table 12-27. AC Programming Specifications
Symbol Description Min Typ Max Unit Notes
T
RSCLK
Rise Time of SCLK 1 20 ns
T
FSCLK
Fall Time of SCLK 1 20 ns
T
SSCLK
Data Set up Time to Falling Edge of SCLK 40 ns
T
HSCLK
Data Hold Time from Falling Edge of SCLK 40 ns
F
SCLK
Frequency of SCLK 0 8 MHz
T
ERASEB
Flash Erase Time (Block) 10 ms
T
WRITE
Flash Block Write Time 40 ms
T
DSCLK
Data Out Delay from Falling Edge of SCLK 45 ns Vdd > 3.6
T
DSCLK3
Data Out Delay from Falling Edge of SCLK 50 ns 3.0 Vdd 3.6
T
ERASEALL
Flash Erase Time (Bulk) 80 ms Erase all Blocks and
protection fields at once
T
PROGRAM_HOT
Flash Block Erase + Flash Block Write Time 100
[14]
ms 0°C Tj 100°C
T
PROGRAM_COLD
Flash Block Erase + Flash Block Write Time 200
[14]
ms -40°C Tj 0°C
Note
14. For the full industrial range, the user must employ a temperature sensor user module (FlashTemp) and feed the result to the temperature argument before writing.
Refer to the Flash APIs Application Note AN2015 at http://www.cypress.com under Application Notes for more information.