Operating instructions

2-3 (E)
DFP-R3000
2-2. Periodic Maintenance Schedule
The following table shows the schedule for periodically checking the main parts of the unit to ensure its
full functions and performance.
It is recommended to use the film running hours of DFP-R3000 as a reference for periodic inspections.
The replacing and adjusting of the following parts are described in “Section 3 Mechanical Parts Replace-
ment and Alignment”.
Checking of the film running hours
To check the film running hours, open the “STATUS” menu of the LCD Panel Menu of the DFP-D3000
connected to the DFP-R3000, and check at the FILMRUN item.
(Refer to “LCD Panel Menu” of DFP-D3000/R3000 OPERATION MANUAL for the details of LCD
panel menu.)
Periodic Check Parts List
n
The replacement hours shown in the following list are not the guarantee term parts.
Use this list as guidelines for the maintenance and inspection. The replacement hours of the parts vary
depending on the operation environment and conditions of the unit.
The replacement hours shown in the following list are tentative.
: Checking and Cleaning
: Checking
: Checking (Adjustment)
: Checking (Grease up)
: Replacement
2-2. Periodic Maintenance Schedule
Check Item C.C.F.S.
/(Note 1)
Inspection Hours (h) Part No.
2500 5000 7500
LED assembly block LED assembly A-8318-476-
Roller guide assembly block Roller guide assembly X-3167-637-
Roller guide (S) assembly X-3168-031-
Sprocket block Sprocket sub assembly X-3168-029-
Sprocket holder assembly X-3168-033-
Brake 3-194-805-
Film retainer roller (PAD roller) 3-185-158-
Tension regulator block Tension regulator holder X-3167-617-
(B) sub assembly
Drum block Drum assembly X-3168-030-
(Note 1) “C.C.F.S.” means “Checking and Cleaning before Film Setting”.