Operating instructions

3-7 (E)
DFP-R3000
3-1-3. Roller guides S2, S3 and T1
The replacement of the roller guide S2, S3 and T1
are the same.
Required Tools
Cleaning cloth : 3-184-527-01
Cleaning fluid : 9-919-573-01
Removal
1. Turn the DFP-R3000 power off.
2. Remove the front panel assembly.
(Refer to the section “1-2. Cabinet Remov-
al”.)
3. Remove the screw (RK4 x 8) and take out
the ornamental washer (ø4), stopper (ø4) and
roller guide S2 (or S3 or T1) from the roller
guide shaft.
Reassembling
4. Wipe the roller guide shaft (marked by )
as shown in figure using the cleaning cloth
moistened with the cleaning fluid.
5. Attach the ornamental washer (ø4), stopper
(ø4) and roller guide S2 (or S3 or T1) in the
reverse orders of procedure 1 through 3
above, and tighten the screw (RK4 x 8) on
the top of the roller guide.
n
Attach the roller guide assembly with the
narrower side of the flange facing down.
Adjustment after the replacement
After the replacing has been completed, perform
the following adjustment/checking.
3-4. Film Running Checking 3-5. Optics
Adjustment (S and P sides)
3-1. Mechanical Parts Replacement
RK4 x 8
RK4 x 8
Ornamental 
washer (ø4)
Stopper (ø4)
Roller guide T1
Roller guide S2
Roller guide shaft
Ornamental washer (ø4)
Stopper (ø4)
RK4 x 8
Roller guide S3
Ornamental washer (ø4)
Stopper (ø4)
Wipe the shaft using cleaning cloth
moistened with cleaning fluid.
Flange is thin.
Flange is thin.
Flange
is thin.
Roller guide shafts