2. P side shading adjustment
Procedure
(1) Input the command C1 (press the “C” key and “1” key) from the PC keyboard at
the screen of the terminal software started and then press the Enter key.
(2) Input the command m100 from the PC keyboard and then press the Enter key.
(3) Input the command k1, 70 from the PC keyboard and then press the Enter key.
(4) Adjust the installed position of the P side LED assembly as follows so that the
output waveform of the oscilloscope CH1 is in the specification mentioned
below.
Specification : The minimum b of the CH1 output
waveform should be above 80% of
maximum a.
Adjustment :
Adjustment of horizontal direction
1 Loosen the two screws A about a half turn.
2 Insert the eccentric driver (ø3-ø5) into the adjustment
hole, and perform the adjustment.
Adjustment of vertical direction
1 Loosen the screw B about a half turn using hex wrench
driver (across 1.27 mm).
2 Turn the support C using nut driver (across 5 mm) to
adjust.
3-2. Optical Source Adjustment
(5) After adjustment has been completed, tighten the loosened screws.
Check that the output waveform of the oscilloscope CH1 after tightening meets
the specification in the above step (4).
LED assembly
(P side)
Vertical 
direction
Support C
Screws A
Horizontal
direction
Adjusting hole
Screw B