Operating instructions

3-21 (E)
DFP-R3000
Adjustment
(5) After the adjustment has been completed, input the
command C0 from the PC keyboard, and then press
the Enter key.
3-4. Film Running Checking
Perform the film running checking when roller guides (S1,
S2, S3 and T1), sprocket SUB assembly, sprocket holder
assembly, brake, tension regulator holder and film retainer
roller are replaced.
Perform the film running checking with DFP-R3000
installed to the projector.
Required Equipment and Tools
Projector
DFP-D3000
Connection cable (Supplied with DFP-R3000)
Alignment film (with data sheet)
Preparation
Remove the OPT cover, drum cover, front panel assembly
and left side panel, and then perform the followings.
(1) Pull out the RD-35 board as shown in the figure below
so that the oscilloscope, etc. can be connected to the
TP terminal.
(2) Install the DFP-R3000 into the projector.
(3) Connect the DFP-R3000 to the DFP-D3000 READER
connector using connection cable.
(4) Load the alignment film into the DFP-R3000 and
projector, and the run the alignment film.
(5) Connect the oscilloscope to the following points on the
RD-35 board.
Oscilloscope RD-35 board
CH1 TP1 (VIDEO)
CH2 TP2 (Trigger)
3-4. Film Running Checking
RD-35 board
Dsub.9P
Pull out
To DFP-D3000
To PC
TP1 (VIDEO)
TP2 (TRIG)
TP3 (CENTER)
TP4 (FG)
E6
E5
SE-437 board (P side)
RV1