CY8C20xx6A/H CapSense Design Guide Doc. No. 001-65973 Rev. *A 25
3.7 SmartSense User Module Parameters
Figure 3-9. PSoC Designer SmartSense Parameters
3.7.1 Shield Electrode Out
A shield electrode is used to reduce parasitic capacitance. This parameter selects where to route the output of the
shield electrode.
Possible values are P0[7] or P1[2].
3.7.2 Sensor Sensitivity
This parameter is used to increase and decrease the sensitivity of a sensor.
Possible values are 0.1 pF, 0.2 pF, 0.3 pF, and 0.4 pF
3.7.3 Multi-Chart for monitoring CapSense user module parameters
Tuning the CapSense system requires you to monitor the CapSense User Module global arrays. Multi-chart helps to
monitor this parameter very easily. Refer to application note AN2397 for more details on the use of the multi-chart
tool.