Specifications

© 2010 Cypress Solutions Complete Manual: CTM-15X Firmware 1.3.0
Open CTM (Revision D)
180
ULCP Remote Configuration Messages
save; 1 = save to NV memory.
Bit 2 is used to select the report destination IP address:
when bit2 is 1 = use the IP address(destination UDP Port number) configured above;
when bit2 is 0 = use the IP address(fixed UDP Port number 6101) of this incoming setup
message.
Bit 3 is used to select the message mode: 1 = ASCII mode (no ULCP header); 0 = with ULCP
header
1 byte
Number of messages to report
8
bytes
Message list: up to 8 messages may be specified. Refer to the above list of possible messages
If the command was not successful then no response is sent.
Response header: 0x57 0xSS 0x03 0x00 0x00 0x18 0xNNNN
Where NNNN is the password.
Response message body: the message body as defined above
Query
Request header: 0x57 0xSS 0x00 0x00 0x00 0x00 0x0000
Request message body: None.
If the command was not successful then no response is sent.
Response header: 0x57 0xSS 0x01 0x00 0x00 0x18 0xNNNN
Where NNNN is the password.
Response message body: the message body as defined above
12.2.8 Delta Position Based Reporting
Setup
Request header: 0x56 0xSS 0x02 0x00 0x00 0x18 0x0000
Request message body:
Hex
Description
4
bytes
Report destination IP address: xx.xx.xx.xx If 0.0.0.0 is set then use the IP address of this incoming
setup message
4
bytes
Report source IP address (the modems IP address): xx.xx.xx.xx
2
bytes
Report destination UDP Port number. If 0 is set then use the port number of this incoming setup
message
2
bytes
Report source UDP port number: set to 6100
2
bytes
Report distance: range 1 to 65535 metres 0 disables distance based reporting