CLUX-UCEC HDMI CEC Control Box Operation Manual CLUX-UCEC
Disclaimers The information in this manual has been carefully checked and is believed to be accurate. Cypress Technology assumes no responsibility for any infringements of patents or other rights of third parties which may result from its use. Cypress Technology assumes no responsibility for any inaccuracies that may be contained in this document. Cypress also makes no commitment to update or to keep current the information contained in this document.
Safety Precautions Please read all instructions before attempting to unpack or install or operate this equipment, and before connecting the power supply. Please keep the following in mind as you unpack and install this equipment: Always follow basic safety precautions to reduce the risk of fire, electrical shock and injury to persons. To prevent fire or shock hazard, do not expose the unit to rain, moisture or install this product near water.
Table of Contents 1. Introduction ……………………..……………………...…........….……. 1 2. Applications …………………..………………….……...................….. 1 3. Package Contents ………………………...........……….................… 1 4. System Requirements ……………..……….........………............……. 1 5. Features …………………………………………......……........…...…… 2 6. Specifications ………………………………...……..........………....…. 2 7. Operation Controls and Functions ……………...……..............…… 7.1 Front Panel .............................................
1. Introduction The HDMI CEC Control Box is a convenient USB device allowing users to control various HDMI devices through their PC. Both sources and displays can be controlled, either with a PC or remote control. This device connects to the PC using a mini USB port, allowing plug and play simplicity and providing power for the device itself, so you don’t have to deal with any cumbersome cables. 2. Applications CEC system remote control over USB for HDMI devices 3.
5. Features HDMI v1.3, HDCP v1.1 & DVI v1.0 compliance Supports full CEC functions Plug and play RS-232 over mini USB Power supplied through the mini USB port Supports EDID bypass Compact and stylish design 6. Specifications Frequency Bandwidth 2.25Gbps (single link) Input Port 1 x HDMI Female Port (Type A Connector) Output Port 1 x HDMI Female Port (Type A Connector) HDMI Audio PCM2, PCM5.1, PCM7.1, Dolby 5.1, DTS 5.
. Operation Controls and Functions 7.1 Front Panel HDMI I / O CLUX-UCEC ① ① HDMI input/output: This slot is where you can connect the output port of your HDMI / DVI source (i.e., DVD, set-top box) or the input ports of an HDMI display using a HDMI / HDMI to DVI adaptor cable. When connecting with an input source, the other HDMI/O must connect with the output port of your display. You cannot control two sources/displays. 7.
. Software installation 8.1 RS-232 Driver Installation Step 1: Insert the provided driver CD into your CD-ROM driver, then execute the FIDIBUS file. Follow the on screen instructions to complete the instillation. NOTE: It is not necessary to install this application if users already have existing RS-232 software. 8.2 Hardware Installation Once the RS-232 driver is installed connect the device to PC/Notebook with mini USB to USB A type cable.
Choose “No, not this time” and Click “Next” . Click “ Browse ” and find “ USB TO RS232 SOFTWAVE ” and click “Nest>”.
Click “Continue Anyway” button. Click “Finish” button Now the PC will show “Found New Hardware” with USB Serial Port. This means your device has been detected.
Your PC will re-run the Found New Hardware Wizard, please repeat the same steps for a full installation. Choose “No, not this time” and click “Next” button.
Choose “Install from a list or specific location (Advanced) and click “Next>” button. Click “Browse” and find “USB TO RS232 SOFTWAVE” and click “Next>” button.
Click the “Finish” button and the PC screen will show a confirmation message that advise a complete installation as shown below.
Step 2: Click START from the left bottom window and select Settings → Control panel → Performance and maintenance → System → System Properties → Hardware → Device Manager → Ports (COM & LPT) → USB Serial Port (COM) 8.3 Software Application Step 1: To install this program, please insert the included CD and double click CLUX_UCED_AP.exe.
Step 2: When the application launches (see below image) the user can select the following features. 1.RS-232 setting: ComPort designated for the CEC control with its BaudRate transmission, click connect to confirm this setting 2. CEC setting: i.e. DVD player sends active commands to a TV, Data Length would include Data Type (CEC), CEC Header (4F), CEC OPCode (82) and 5bytes of data. Press Transmit to confirm the setting (Detail setting please refers to section 9) 3. Common use CEC command. 4.
0x0D 0x0F 0x1A 0x1B 0x32 0x36 0x41 0x42 0x44 0x46 0x47 0x64 0x80 0x81 0x82 0x83 0x84 0x85 0x86 0x87 0x89
10.
11.
A Acronyms Acronym Complete Term CEC Consumer Electronics Control DVI Digital Visual Interface EDID Extended Display Identification Data HDCP High-bandwidth Digital Content Protection HDMI High-Definition Multimedia Interface VGA Video Graphics Array WUXGA Wide Ultra Extended Graphics Array 15
CYPRESS TECHNOLOGY CO., LTD. Home page: http://www.cypress.com.