User manual

CY7C67200
Document #: 38-08014 Rev. *G Page 46 of 78
HSS Transmit Gap Register [0xC074] [R/W]
Figure 50. HSS Transmit Gap Register
Register Description
The HSS Transmit Gap register is only valid in block transmit mode. It allows for a programmable number of stop bits to be inserted
thus overwriting the One Stop Bit in the HSS Control register. The default reset value of this register is 0x0009, equivalent to two
stop bits.
Transmit Gap Select (Bits [7:0])
The Transmit Gap Select field sets the inactive time between transmitted bytes. The inactive time = (Transmit Gap Select – 7) *
bit time. Therefore an Transmit Gap Select Value of 8 is equal to having one Stop bit.
Reserved
All reserved bits must be written as ‘0’.
HSS Data Register [0xC076] [R/W]
Figure 51. HSS Data Register
Register Description
The HSS Data register contains data received on the HSS port (not for block receive mode) when read. This receive data is valid
when the Receive Ready bit of the HSS Control register is set to ‘1’. Writing to this register initiates a single byte transfer of data.
The Transmit Ready Flag in the HSS Control register must read ‘1’ before writing to this register (this avoids disrupting the
previous/current transmission).
Data (Bits [7:0])
The Data field contains the data received or to be transmitted on the HSS port.
Reserved
All reserved bits must be written as ‘0’.
Bit # 15 14 13 12 11 10 9 8
Field Reserved
Read/Write - - - - - - - -
Default 0 0 0 0 0 0 0 0
Bit # 7 6 5 4 3 2 1 0
Field Transmit Gap Select
Read/Write R/W R/W R/W R/W R/W R/W R/W R/W
Default 0 0 0 0 1 0 0 1
Bit # 15 14 13 12 11 10 9 8
Field Reserved
Read/Write - - - - - - - -
Default X X X X X X X X
Bit # 7 6 5 4 3 2 1 0
Field Data
Read/Write R/W R/W R/W R/W R/W R/W R/W R/W
Default X X X X X X X X
[+] Feedback