CSC-5500 Multi Input Scaler Operation Manual
DISCLAIMERS The information in this manual has been carefully checked and is believed to be accurate. Cypress Technology assumes no responsibility for any infringements of patents or other rights of third parties which may result from its use. Cypress Technology assumes no responsibility for any inaccuracies that may be contained in this document. Cypress also makes no commitment to update or to keep current the information contained in this document.
SAFETY PRECAUTIONS Please read all instructions before attempting to unpack, install or operate this equipment and before connecting the power supply. Please keep the following in mind as you unpack and install this equipment: • Always follow basic safety precautions to reduce the risk of fire, electrical shock and injury to persons. • To prevent fire or shock hazard, do not expose the unit to rain, moisture or install this product near water. • Never spill liquid of any kind on or into this product.
CONTENTS 1. Introduction �������������������������������������������� 1 2. Applications ������������������������������������������� 1 3. Package Contents �������������������������������� 1 4. System Requirements ���������������������������� 1 5. Features �������������������������������������������������� 2 6. Operation Controls and Functions ������� 3 6.1 Front Panel �����������������������������������������3 6.2 Rear Panel �����������������������������������������4 6.
1. INTRODUCTION This Multi Input Scaler has Composite Video, Component Video, PC (VGA), and HDMI inputs and can switch and scale the signal to HDMI or VGA with audio outputs. It supports HDMI output resolutions up to 1080p/WUXGA and Analog Digital Conversion (ADC) and Digital Analog Conversion (DAC) allowing a wide range of AV signals to be displayed on a HDMI or VGA display. Further, the On-screen Display (OSD), IR remote, RS-232, IP and on-panel controls make this product very versatile. 2.
5.
6. OPERATION CONTROLS AND FUNCTIONS 6.1 Front Panel POWER CV COMP PC 1 PC 2 PC 3 HDMI 1 HDMI 2 HDMI 3 720P MENU - + • ENTER XGA 1 2 3 4 5 6 1 POWER Button and LED: Press this button to switch the device on or to set it to standby mode. Once the device is connected to an active power supply and the Power Switch on the back panel is turned on, the LED will illuminate and the device will switch on automatically.
6.2 Rear Panel 1 2 IR IN 3 6 SERVICE R RS232 OUTPUT HDMI 1 HDMI 2 4 COAX PC/HD L INPUT AUDIO AUDIO HDMI 1 HDMI 2 HDMI 3 PC 1 7 CONTROL PC 2 PC 3 Cr/Pr Cb/Pb Y R L POWER CV DC 5V 5 8 1 IR IN: Connect the supplied IR extender to receive the IR signal from the included IR remote. Ensure that the remote is within the direct line-of-sight of the IR extender. 2 SERVICE: Reserved for manufacturer use only.
3) 3.5mm Mini-jacks: Connect to source's L/R output with 3.5mm mini-jack for audio signal conversion. Note: For HDMI signals you can select in the OSD Menu whether you require audio from the HDMI (AUTO) or from the analog audio inputs (EXT) 4) YCbCr/YPbPr + L/R: Connect to source equipment such as a DVD player for both video and audio signal conversion. 5) CV + L/R: Connect to a composite video source such as a video/DVD player for both video and audio signal conversion.
6.
6.
COMMAND DESCRIPTION S INPUT HDCP 0/1 0=ON R INPUT HDCP Apple Computers Only.
COMMAND DESCRIPTION S AUDIO DELAY 0~3 0=OFF 1=40ms R AUDIO DELAY Reports the numeric equivalent for the AUDIO DELAY setting (as above) S AUDIO MUTE 0/1 0=ON R AUDIO MUTE Reports the numeric equivalent for the AUDIO MUTE setting (as above) S HDMI AUDIO 0/1 0=AUTO R HDMI AUDIO Reports the numeric equivalent for HDMI AUDIO setting (as above) S KEY LOCK 0/1 0=ENABLE R KEY LOCK Reports the numeric equivalent for KEY LOCK setting (as above) S FREERUNCOLOR 0/1 0=BLACK R FREERUNCOLOR Reports th
Note: 1. Resolution settings 0~13 are RGB encoded. Resolution settings 14~21 are YUV encoded. 2. RS-232 commands will be not executed unless followed with a carriage return (CR) command and for some systems a Line feed (LF) command. Commands are case-insensitive.
6.
MAIN MENU SUB MENU 3RD MENU DISPLAY SIZE OVER SCAN 4TH MENU FULL* FOLLOW INPUT PAN SCAN LETTER BOX UNDER 2 UNDER 1 MODE INFO OFF INFO* ON INPUT HDCP OFF (HDMI mode ON* only) PC AUTO SETUP (PC mode only) H_POSITION V_POSITION PHASE CLOCK WXGA/XGA XGA* WXGA RESET 12
MAIN MENU SUB MENU 3RD MENU COLOR CONTRAST 0~60 (30) BRIGHTNESS 0~60 (30) COLOR R 0~1023 (512) G 0~1023 (512) B 0~1023 (512) R OFFSET 0~1023 (512) G OFFSET 0~1023 (512) B OFFSET 0~1023 (512) HUE 0~60 (30) SATURATION 0~60 (30) SHARPNESS 0~30 (0) NR. OFF* LOW MIDDLE HIGH AUDIO VOLUME 0~100 (100) DELAY OFF* 40ms 110ms 150ms SOUND ON* MUTE SOURCE (HDMI mode only)*1 13 AUTO* EXT.
MAIN MENU SUB MENU SETUP FACTORY 3RD MENU 4TH MENU RESET*2 KEY LOCK OFF* ON POWER SAVE OFF* ON IP MODE DHCP* STATIC SET STATIC IP IP ADDRESS 0.0.0.0.~ 255.255.255.255*3 SUBNET MASK 0.0.0.0.~ 255.255.255.255*4 DEF.GETWAY 0.0.0.0.~ 255.255.255.255*5 INFORMATION FREERUN BLACK COLOR BLUE* INPUT OUTPUT REVISION IP ADDRESS Note: 1.
2. The FACTORY RESET option in the OSD menu will only reset part of settings. For a complete reset of the system, please use the reset button on the remote control. 3. 192.168.0.1 (Default setting). 4. 255.255.255.0 (Default setting). 5. 192.168.0.254 (Default setting). 6. Items in BOLD with an asterisk (*) are the Factory default settings. Items in brackets are the default values for those settings. 6.
Once in the command line interface (CLI) type 'telnet' along with the IP address of the unit you wish to control (see below for reference). This will bring us into the device which we wish to control. Note: The IP address can be obtained from the OSD menu under Information. If the IP is changed then the IP Address required for Telnet access will also needs to be change accordingly. Type '?' to list all the available commands (see below for reference).
6.8 Web GUI Control On a PC/Laptop that is connected to same active network as the Scaler, open a web browser and type device's IP address on the web address entry bar. The browser will bring up the control page of the Scaler (see below for reference). Note: The IP address can be obtained from the OSD menu under Information. If the IP is changed then the IP Address required for Telnet access will also needs to be changed accordingly.
6.
6.
7.
8. SPECIFICATIONS Input Ports 3×HDMI, 3×VGA, 1×Component Video, 1×Composite Video, 2×RCA (Analog Stereo L/R), 6×3.5mm Mini-jack, 1×Extender, 1×USB (Service), 1×RJ45 (Control), 1×RS-232 (Control) Output Ports 2×HDMI, 1×VGA/Component Video, 1×Coaxial, 1×3.
9.
CYPRESS TECHNOLOGY CO., LTD Home page: http://www.cypress.com.