DC Programming Specifications
Tab le 2 4 lists the guaranteed maximum and minimum specifications for the voltage and temperature ranges: 4.75V to 5.25V and -40°C
T
A
85°C, 3.0V to 3.6V and -40°C T
A
85°C, or 2.4V to 3.0V and -40°C T
A
85°C, respectively. Typical parameters apply to
5V, 3.3V, or 2.7V at 25°C and are for design guidance only.
Table 24. DC Programming Specifications
Symbol Description Min Typ Max Units Notes
Vdd
IWRITE
Supply Voltage for Flash Write Operations 2.70 V
I
DDP
Supply Current During Programming or Verify 5 25 mA
V
ILP
Input Low Voltage During Programming or
Verify
0.8 V
V
IHP
Input High Voltage During Programming or
Verify
2.2 V
I
ILP
Input Current when Applying Vilp to P1[0] or
P1[1] During Programming or Verify
0.2 mA Driving internal pull down resistor.
I
IHP
Input Current when Applying Vihp to P1[0] or
P1[1] During Programming or Verify
1.5 mA Driving internal pull down resistor.
V
OLV
Output Low Voltage During Programming or
Verify
Vss +
0.75
V
V
OHV
Output High Voltage During Programming or
Verify
Vdd
-
1.0
Vdd V
Flash
ENPB
Flash Endurance (per block) 50,000 Erase/write cycles per block.
Flash
ENT
Flash Endurance (total)
[11]
1,800,
000
Erase/write cycles.
Flash
DR
Flash Data Retention 10 Years
Note
11. A maximum of 36 x 50,000 block endurance cycles is allowed. This may be balanced between operations on 36x1 blocks of 50,000 maximum cycles each, 36x2
blocks of 25,000 maximum cycles each, or 36x4 blocks of 12,500 maximum cycles each (to limit the total number of cycles to 36x50,000 and that no single block
ever sees more than 50,000 cycles). For the full industrial range, the user must employ a temperature sensor user module (FlashTemp) and feed the result to
the temperature argument before writing. Refer to the Flash APIs Application Note AN2015 at http://www.cypress.com under Application Notes for more
information.