Full Speed USB Controller Specification Sheet

CY7C64215
Document 38-08036 Rev. *C Page 19 of 30
DC POR and LVD Specifications
The following table lists guaranteed maximum and minimum specifications for the voltage and temperature ranges: 4.75V to 5.25V
and 0°C <
T
A
< 70°C, or 3.0V to 3.6V and 0°C < T
A
< 70°C, respectively. Typical parameters apply to 5V or 3.3V at 25°C and are for
design guidance only.
Note The bits PORLEV and VM in the table below refer to bits in the VLT_CR register. See the PSoC Mixed-Signal Array Technical
Reference Manual for more information on the VLT_CR register.
Table 16. DC POR and LVD Specifications
Parameter Description Min Typ Max Unit Notes
V
PPOR0R
V
PPOR1R
V
PPOR2R
Vdd Value for PPOR Trip (positive ramp)
PORLEV[1:0] = 00b
PORLEV[1:0] = 01b
PORLEV[1:0] = 10b
2.91
4.39
4.55
V
V
V
V
PPOR0
V
PPOR1
V
PPOR2
Vdd Value for PPOR Trip (negative ramp)
PORLEV[1:0] = 00b
PORLEV[1:0] = 01b
PORLEV[1:0] = 10b
2.82
4.39
4.55
V
V
V
V
PH0
V
PH1
V
PH2
PPOR Hysteresis
PORLEV[1:0] = 00b
PORLEV[1:0] = 01b
PORLEV[1:0] = 10b
92
0
0
mV
mV
mV
V
LVD0
V
LVD1
V
LVD2
V
LVD3
V
LVD4
V
LVD5
V
LVD6
V
LVD7
Vdd Value for LVD Trip
VM[2:0] = 000b
VM[2:0] = 001b
VM[2:0] = 010b
VM[2:0] = 011b
VM[2:0] = 100b
VM[2:0] = 101b
VM[2:0] = 110b
VM[2:0] = 111b
2.86
2.96
3.07
3.92
4.39
4.55
4.63
4.72
2.92
3.02
3.13
4.00
4.48
4.64
4.73
4.81
2.98
[4]
3.08
3.20
4.08
4.57
4.74
[5]
4.82
4.91
V
V
V
V
V
V
V
V
Notes
4. Always greater than 50 mV above PPOR (PORLEV = 00) for falling supply
5. Always greater than 50 mV above PPOR (PORLEV = 10) for falling supply
[+] Feedback [+] Feedback