Specifications

#
#
of 2 17
This manual covers the operation and setup of the Cypress Suprex RF SPX-5000 series wireless units. #
#
Overview:#
#
The SPX-5000 series of RF Wireless solutions provides a wireless bridge from card readers with gates or door
hardware to most access control manufacturers panels. The SPX or Suprex® products include both the remote
( Door/Gate ) unit and the central ( AC Panel ) unit. In the case of the SPX-5000 series of wireless products optional
repeaters / extenders are also available.#
#
Features:!
#
-- Includes complete solution with remote ( reader/gate/door ) and central ( panel ) interface.#
-- Service mode for setup and configuration.#
--“Quiet” protocol to conserve bandwidth and power#
-- Field configurable reader formats#
-- Multifunction indicator for determining operational status of the unit#
-- Auxiliary I/O connections available for Door/Gate/Panel status signaling. #
-- Multiplexing of RF bridge providing for additional door/gate on a single RF link. #
-- Economical expansion capabilities using Suprex Lynk technology#
#
RF Specifications:!
#
2.4GHz or 900Mhz frequency#
AES Encryption upon request
Cypress Suprex SPX-5000 Series Overview
Electrical and Mechanical Specifications
Cypress Computer Systems, Inc. Lapeer, MI 48446 www.cypresscomputer.com
© 2012 Cypress Computer Systems Inc.
Physical
Weatherproof Enclosure - ABS - IP65#
SPX units 6.75” x 4.75” x 2.10” (Each unit)
Temp
Storage(-55˚C to + 150˚C) - Operating(-40˚C to +80˚C)
Humidity
95% (non-condensing)
Power
Input
Unreg Input 8 to 16 VDC* @ 500mA Max #
Unreg Input 8 to 24 VDC @ 500mA Max ( IOX-7000 )
Output
+5VDC @100mA ( except IOX-7000 )
Data I/O
Interface
Reader -Wiegand, Strobed (Clock & Data), F/2F#
LED - 0 - 30V
Relays
Max Switching
(220Vdc 30W (resistive) 1A)
(250Vac 37.5VA 1A)
Running Spec with load
(30Vdc 1A (resistive), 1 x 10
5
operations at 20
o
C
125Vac .3A (resistive), 1 x 10
5
operations at 20
o
C