Rigging Manual convert 15A series El colgado del equipo sólo debe realizarse utilizando los herrajes de colgado recomendados y por personal cualificado. No cuelgue la caja de las asas. The appliance should be flown only from the rigging points and by qualified personnel. Do not suspend the box from the handles.
CONTENTS RIGGING SYSTEM 3a4 VERTICAL ARRAY FOR “-RA” VERSIONS 5a8 HORIZONTAL ARRAY FOR “-RA” VERSIONS 9 a 12 VERTICAL ARRAY FOR “-A” VERSIONS 13 a 16 HORIZONTAL ARRAY FOR “-A” VERSIONS 17 a 19 Manual de Colgado / convert 15A series / Rigging Manual
RIGGING SYSTEM Warning This manual contains needed information for flying D.A.S. Audio line array systems, description of the elements and safety precautions. To perform any operations related to flying the system, read the present document first, and act on the warnings and advice given. The goal is to allow the user to become familiar with the mechanical elements required to fly the acoustic system, as well as the safety measures to be taken during set-up and teardown.
Manual de Colgado / convert 15A series / Rigging Manual CONVERT 1560A CONVERT 1590A CONVERT 1560RA CONVERT 1590RA AXA-CV15 AX-CONVERT15B AX-CONVERT15 VERTICAL ARRAY AXA-CV15 AXA-CV15H AXA-CV15H UNIVERSAL FLY BAR (UFB) UNIVERSAL FLY BAR (UFB) HORIZONTAL ARRAY
VERTICAL ARRAY (‘-RA’ versions) For this mounting type convert1560RA or convert1590RA are required. This is the simplest way because only AX-CONVERT15 rigging accessory is required for just one lift motor. In case of using two lift motors, AX-CONVERT15 and PICKUP AX-CONVERT15 will be needed. Be conscious that rigging must be performed by highly skilled workers, with an adequate knowledge of the equipment and fittings to use. Workers must also know the local safety regulations.
Junction between enclosures Suppose we join several enclosures to create a vertical array mounting type for ‘-RA’ versions. We will place the first two enclosures, as in Figure1, one above the other on a flat surface. The rigging system ends are aligned and prevent them from moving while acting on the locking pins. To join the two enclosures with the rigging system we will act on the rear pin (shown in red in Figure 2) and also on the lever adjacent to it. Figure 1 Refer to Figure 3.
Figure 5 Remember to repeat the junction process acting on the pins marked in Figure 6. The enclosures will remain together securely.
Finally, join AX-CONVERT15 with the top enclosure. First, unite each of the side parts of the AX facing the cog blade system of the side piece with the top enclosure caps. Act on the safety pin of this side of the enclosure as we explained before (see the figures below). To finish, place the AX bar with the safety pins in the holes of the top part which correspond to the right angles.
HORIZONTAL ARRAY (‘-RA’ versions) For this mounting type convert1560RA or convert1590RA are required. It is very simple because only UFB and AXA-CV15H rigging accessories are required for just one lift motor. In case of using two lift motors, another UFB will be needed. Be conscious that rigging must be performed by highly skilled workers, with an adequate knowledge of the equipment and fittings to use. Workers must also know the local safety regulations.
Junction between enclosures Suppose we join several enclosures to create an horizontal array mounting type for ‘-RA’ versions. We will place the first two enclosures, as in Figure7, one above the other on a flat surface. The rigging system ends are aligned and prevent them from moving while acting on the locking pins. To join the two enclosures with the rigging system we will act on the rear pin (shown in red in Figure 9) and also on the lever adjacent to it.
In the Figure 12 we can see the mounting of three enclosures. We should add more enclosures in the same way to the desired units. Also, we can choose to mount systems onto SUBs as shown in Figure 13. Figure 12 Figure 13 If we choose a rigging mounting type, after joining the enclosures place the AXA-CV15H and the UFB (one or two depending on the lift motors).
Next, for two or more enclosure sets the different mounting positions of AXA-CV15H are shown. 3 enclosure mounting 4 enclosure mounting 5 enclosure mounting 6 enclosure mounting The use of the UFB will result as shown below. If two lift motors are used, add another UFB.
VERTICAL ARRAY (‘-A’ versions) This mounting type convert1560A or convert1590A are required. Some AXA-CV15 and one AX-CONVERT15B for one lift motor. In case of using two lift motors, a PICK UP AX-CONVERT15 will be needed. Be conscious that rigging must be performed by highly skilled workers, with an adequate knowledge of the equipment and fittings to use. Workers must also know the local safety regulations.
Repeat the process on the other side of the enclosures (Figure 17 and Figure 18). If we don´t mount the third enclosure we will mount the AX-CONVERT15B and, in this case, we will follow the instructions shown in Figures 19 to 22. Figure 17 Given the coverage angles, more than three enclosures won´t be needed.
Now, mount the side parts of the AX-CONVERT15B like the next figures show. Figure 23 Figure 24 Figure 25 Figure 26 After that, if we are going to rig the system with one lift motor, we will mount the AX-CONVERT15B crowbar like the next figures show.
If we rig the system with two lift motors mount the AX-CONVERT15B crowbar and a PICK UP AXCONVERT15B like the next figures show.
HORIZONTAL ARRAY (‘-A’ versions) This setup is composed of convert 1560A or convert 1590A and is the most complex because it requires a preview planification. The following rigging accessories are required: UFB, AXA-CV15 and AXA-CV15H. In case of using two lift motors, another UFB will be needed. Be conscious that rigging must be performed by highly skilled workers, with an adequate knowledge of the equipment and fittings to use. Workers must also know the local safety regulations.
3 enclosure mounting 4 enclosure mounting 5 enclosure mounting (max. recommended) Also, we can choose to mount systems onto SUBs like the figure on the right shows. In this case secure the enclosures to prevent tipping.
If we choose the rigging mounting we will have to mount a UFB for one lift motor. If we use two motors, another UFB will be needed. In both cases, the maximum recommended number of enclosures for this set is 5 units. Be conscious that rigging must be performed by highly skilled workers, with an adequate knowledge of the equipment and fittings to use. Workers also must know the local safety regulations.
RM_CV15_01_EN www.dasaudio.com D.A.S. AUDIO, S.A. C/. Islas Baleares, 24 46988 Fuente del Jarro Valencia, SPAIN Tel. 96 134 0525 Tel. Intl. +34 96 134 0860 Fax 96 134 0607 Fax Intl. +34 96 134 0607 D.A.S. AUDIO OF AMERICA, INC. Sunset Palmetto Park 6816 NW 77th Court. Miami, FL. 33166 - U.S.A. TOLL FREE: 1-888DAS4USA Tel. +1 305 436 0521 Fax +1 305 436 0528 D.A.S. AUDIO ASIA PTE. LTD. 25 Kaki Bukit Crescent #01-00/02-00 Kaki Bukit Techpark 1 Singapore 416256 Tel.