User`s manual

RIGGING SYSTEM
Accesories description
Introduction
variant 25A
Connecting Link
Absolutely no risks should be taken with
regards to public safety. When flying enclosures
from ceiling support structures, extreme care
should be taken to assure the load bearing
capabilities of the structures so that the installation
is absolutely safe. Do not fly enclosures from
unsafe structures. Consult a certified professional if
needed. All flying accessories that are not supplied
by D.A.S. Audio are the user's responsibility. Use
at your own risk.
variant 112A
Biela
Cam link
15
This section contains needed information for
flying D.A.S. Audio line array systems, description
of the elements and safety precautions. To perform
any operations related to flying the system, read
the present document first, and act on the
warnings and advice given. The goal is to the allow
the user to become familiar with the mechanical
elements required to fly the acoustic system, as
well as the safety measures to be taken during
set-up and teardown. Additional information is
included in the document System Guide which can
be found on the D.A.S. website.
Only experienced installers with adequate
knowledge of the equipment and local safety
regulations should fly speaker boxes. It is the
user's responsibility to ensure that the systems to
be flown (including flying accessories) comply with
state and local regulations.
The working load limits in this manual are the
results of tests by independent laboratories. It is
the user's responsibility to stay within safe limits. It
is the user's responsibility to follow and comply
with safety factors, resistance values, periodical
supervisions and warnings given in this manual.
Product improvement by means of research and
development is on going at D.A.S. Specifications
are subject to change without notice.
To this date, there is no international standard
regarding the flying of acoustic systems. However,
it is common practice to apply 5:1 safety factors
for enclosures and static elements. For slings and
elements exposed to material fatigue due to
friction and load variation the following ratios must
be met; 5:1 for steel cable slings, 4:1 for steel
chain slings and 7:1 polyester slings. Thus, an
element with a breaking load limit of 1000 kg may
be statically loaded with 200 kg (5:1 safety factor)
and dynamically loaded with 142 Kg (7:1 safety
factor).
When flying a system, the working load must
be lower than the resistance of each individual
flying point in the enclosure, as well as each box.
Hanging hardware should be regularly inspected
and suspect units replaced if in doubt. This is
important to avoid injury and absolutely no risks
should be taken in this respect. It is highly
recommended that you implement an inspection
and maintenance program on flying elements,
including reports to be filled out by the personnel
that will carry out the inspections. Local
regulations may exist that, in case of accident,
may require you to present evidence of inspection
reports and corrective actions after defects were
found.
D.A.S. Audio variant 25A, variant 18A and variant
112A units include two rigging structures on each
side of the enclosure. Manufactured from stainless
steel and aluminum, they are affixed with special
M8 crop resistant screws to the wood sides on
both models. A special connecting link is part of
each rigging structure and allows for both stacking
or flying with splay angles ranging from to 10º in
increments (variant 25A) or angles ranging from
12º to 15º (variant 112A).
In order to set up the splay angles the quick
release pins supplied with each unit must be used.
4 quick release pins are provided with variant
25A/112A and 6 quick release pins with the variant
18A.