DGS-1510 Series Gigabit Ethernet SmartPro Switch CLI Reference Guide
209
low
Specifies that when the operating parameter falls below the low
threshold this value, it indicates an abnormal status.
alarm
Specifies to configure the high and low threshold value condition.
warning
Specifies to configure the high and low warning threshold conditions.
mwatt VALUE
Specifies the power threshold value in milliwatts. This value must be
between 0 and 6.5535.
dbm VALUE
Specifies the power threshold value in dBm. This value must be
between -40 and 8.1647.
Default
None.
Command Mode
Global Configuration Mode.
Command Default Level
Level: 12.
Usage Guideline
Only SFP/SFP+ port interfaces with optical modules, with transceiver monitoring capability, are valid for
this configuration.
This command configures the RX power thresholds on the specified port. This value will be stored both in
the system and in the SFP/SFP+ transceivers and be converted to the 16-bit format and then written into
the SFP module.
If the SFP module configured does not support the threshold change, the user-configured threshold is just
stored in the system and the displayed value will be the user-configured threshold. If there is no user-
configured threshold, the displayed value will always reflect the factory preset value defined by the vendor.
The no form of this command has the effect to clear the configured threshold stored in system. It does not
change the threshold stored in the SFP/SFP+ transceivers. Use no form of the command to prevent
threshold values in newly inserted SFP/SFP+ transceivers from being altered.
Example
This example shows how to configure the RX power low warning threshold as 0.135 mW on interface
eth3/0/1.
Switch# configure terminal
Switch(config)# transceiver-monitoring rx-power eth3/0/1 low warning mwatt 0.135
Switch(config)#
21-7 transceiver-monitoring temperature
This command is used to configure the temperature thresholds for the specified port. Use the no form of
the command to remove the configuration.
transceiver-monitoring temperature INTERFACE-ID {high | low} {alarm | warning} VALUE
no transceiver-monitoring temperature INTERFACE-ID {high | low} {alarm | warning}
Parameters
INTERFACE ID
Specifies the interface to modify.
high
Specifies that when the operating parameter rises above this high