Owners manual

DGS-1510 Series Gigabit Ethernet SmartPro Switch CLI Reference Guide
23
high
(Optional) Specifies the high threshold of the temperature in Celsius.
The range is from -100 to 200.
low
(Optional) Specifies the low threshold of the temperature in Celsius.
The range is from -100 to 200. The low threshold must be smaller than
the high threshold.
Default
None.
Command Mode
Global Configuration Mode.
Command Default Level
Level: 12.
Usage Guideline
This command is used to configure the environment temperature threshold which corresponds to the
normal range of the temperature defined for the sensor. The low threshold must be smaller than the high
threshold. The configured range must fall within the operational range which corresponds to the minimum
and maximum allowed temperatures defined for the sensor. When the configured threshold is crossed, a
notification will be sent.
Example
This example shows how to configure the environment temperature thresholds for thermal sensor ID 1 on
unit 1.
Switch# configure terminal
Switch(config)# environment temperature threshold unit 1 thermal 1 high 100 low 20
Switch(config)#