Owners manual

DGS-1510 Series Gigabit Ethernet SmartPro Switch CLI Reference Guide
450
Command Mode
EXEC Mode or Any Configuration Mode.
Command Default Level
Level: 1.
Usage Guideline
This command is used to display the PoE status of ports, power inline configuration status, statistic
counters, the measurement result, and the data link layer classification information. If the interface ID is
not specified with this command, then all PoE interfaces will be displayed. Only the PoE capable
interfaces are displayed.
Example
This example shows how to display the PoE power inline status.
Switch# show poe power-inline status
Interface State Class Max(W) Used(W) Description
-----------------------------------------------------------------------------
eth3/0/1 delivering class-1 4 3.4 IP-camera-1
eth3/0/2 delivering class-2 10 6.3 12345678901234567890123456789012
!--- Output suppressed...
eth4/0/1 delivering class-3 15.4 13.0
eth4/0/2 delivering class-3 15.4 12.4
eth4/0/3 disabled n/a 0 0
eth4/0/4 searching n/a 11.0 0
!--- Output suppressed...
eth5/0/24 disabled n/a 0 0
eth5/0/25 faulty[2] n/a 0 0
Faulty code:
[1] MPS (Maintain Power Signature) Absent
[2] PD short
[3] Overload
[4] Power Denied
[5] Thermal Shutdown
[6] Startup Failure
[7] Classification Failure
Switch#
Display Parameters
Interface
The PoE interface ID.
State
The port status can be of the following:
DisabledThe PSE function is disabled.
SearchingThe remote PD is not connected.
RequestingThe remote PD is inserted, but the PSE doesn’t provide
power yet.
Delivering The remote PD is now powering by PoE system.
Faulty[X]The device detection or a powered device is in a faulty
state. X is the error code number.
[1] - MPS (Maintain Power Signature) Absent.