Owners manual

DGS-1510 Series Gigabit Ethernet SmartPro Switch CLI Reference Guide
454
Interface
The PoE interface ID.
Power type
The power type field which is in the Power via MDI TLV from PSE or
PD LLDP packet.
Power source
The power source field which is in the Power via MDI TLV from PSE or
PD LLDP packet.
Power priority
The power priority field which is in the Power via MDI TLV from PSE or
PD LLDP packet.
PD requested power value
The PD requested power value field which is in the Power via MDI TLV
from PSE or PD LLDP packet.
PSE allocated power value
The PSE allocated power value field which is in the Power via MDI
TLV from PSE or PD LLDP packet.
50-10 show poe power module
This command is used to display the setting and actual values of the power modules.
show poe power module [unit UNIT-ID] [detail]
Parameters
UNIT-ID
Specifies the stacking unit’s ID to be displayed. This parameter is only
available, if stacking is enabled.
detail
(Optional) Specifies to display more detailed chip parameter
information.
Default
None
Command Mode
EXEC Mode or Any Configuration Mode.
Command Default Level
Level: 1.
Usage Guideline
This command displays the detailed power information and PoE chip parameters for PoE modules.
Example
This example shows how to display the PoE power system’s power information.
Switch#show poe power module
Unit Delivered(W) Power Budget(W) Usage-Threshold(%) Preempt Trap State
---------------------------------------------------------------------------
1 0 193 99 Disabled Disabled
Switch#
Display Parameters