System information
DGS-3000 Series Layer 2 Managed Gigabit Switch Web UI Reference Guide
102
MLD Snooping Settings
Users can configure the settings for MLD snooping.
To view the following window, click L2 Features > L2 Multicast Control > MLD Snooping > MLD Snooping
Settings, as show below:
Figure 4-56 MLD Snooping Settings window
The fields that can be configured are described below:
Parameter Description
MLD Snooping State
Click to enable or disable the MLD snooping state.
Max Learning Entry Value
(1-1024)
Enter the maximum learning entry value.
Click the Apply button to accept the changes made for each individual section.
Click the Edit button to configure the MLD Snooping Parameters Settings for a specific entry.
Click the Modify Router Port link to configure the MLD Snooping Router Port Settings for a specific entry.
Enter a page number and click the Go button to navigate to a specific page when multiple pages exist.
After clicking the Edit button, the following page will appear:
Figure 4-57 MLD Snooping Parameters Settings window
The fields that can be configured are described below:
Parameter Description
Query Interval (1-65535)
Specify the amount of time in seconds between general query transmissions. The
default setting is 125 seconds.
Max Response Time (1-
25)
The maximum time in seconds to wait for reports from listeners. The default setting
is 10 seconds.
Robustness Value (1-7)
Provides fine-tuning to allow for expected packet loss on a subnet. The value of the
robustness variable is used in calculating the following MLD message intervals: