System information
DGS-3000 Series Layer 2 Managed Gigabit Switch Web UI Reference Guide
323
authentation failure notification.
Binding: 1: swSingleIPMSID
2: swSingleIPMSMacAddr
swSingleIPMSnewRoot
Commander switch will send swSingleIPMSnewRoot
notification to indicated
host when it Member generate new root notification.
Binding: 1: swSingleIPMSID
2: swSingleIPMSMacAddr
1.3.6.1.4.1.171.12.8.6.0.16
swSingleIPMSTopologyChang
e
Commander switch will send
swSingleIPMSTopologyChange notification to indicated
host when it Member generate topology chnage
notification.
Binding: 1: swSingleIPMSID
2: swSingleIPMSMacAddr
1.3.6.1.4.1.171.12.8.6.0.17
swDdmAlarmTrap
The trap is sent when any parameter value exceeds the
alarm threshold value or recover to normal status
depending on the configuration of the trap action.
Binding: 1: swDdmPort
2: swDdmThresholdType
3: swDdmThresholdExceedType
4: swDdmThresholdExceedOrRecover
1.3.6.1.4.1.171.12.72.4.0.1
swDdmWarningTrap
The trap is sent when any parameter value exceeds the
warning threshold value or recover to normal status
depending on the configuration of the trap action.
Binding: 1: swDdmPort
2: swDdmThresholdType
3: swDdmThresholdExceedType
4: swDdmThresholdExceedOrRecover
1.3.6.1.4.1.171.12.72.4.0.2
agentGratuitousARPTrap
This trap is sent when there is an IP address conflict.
Binding: 1: agentGratuitousARPIpAddr
2: agentGratuitousARPMacAddr
3: agentGratuitousARPPortNumber
4: agentGratuitousARPInterfaceName
1.3.6.1.4.1.171.12.1.7.2.0.5
agentCfgOperCompleteTrap
The trap is sent when the configuration is completely
saved, uploaded or downloaded.
Binding: 1: unitID
2: agentCfgOperate
3: agentLoginUserName
1.3.6.1.4.1.171.12.1.7.2.0.9
agentFirmwareUpgrade
This trap is sent when the process of upgrading the
firmware via SNMP has finished.
Binding: 1: swMultiImageVersion
1.3.6.1.4.1.171.12.1.7.2.0.7
swPowerStatusChg
Power Status change notification. The notification is
issued
when the swPowerStatus changes in the following
cases:
lowVoltage -> overCurrent.
lowVoltage -> working.
lowVoltage -> disconnect.
lowVoltage -> connect.
overCurrent -> lowVoltage.
overCurrent -> working.
overCurrent -> disconnect.
overCurrent -> connect.
working -> lowVoltage.
working -> overCurrent.
working -> connect.
working -> disconnect.
fail -> connect.
fail -> disconnect.
connect -> lowVoltage.
connect -> overCurrent.
connect -> working.
connect -> disconnect.
disconnect -> lowVoltage.
1.3.6.1.4.1.171.12.11.2.2.2.0.1