Model DP-301P Multiprotocol Ethernet/Fast Ethernet Print Server Hardware Guide Rev. 01 (March 1999) 6DP301P...
Limited Warranty Hardware: D-Link warrants its hardware products to be free from defects in workmanship and materials, under normal use and service, for the following periods measured from date of purchase from D-Link or its Authorized Reseller: Product Type Complete products Spare parts and spare kits Warranty Period One year 90 days The one-year period of warranty on complete products applies on condition that the product's Registration Card is filled out and returned to a D-Link office within ninety (9
Software: Warranty service for software products may be obtained by contacting a D-Link office within the applicable warranty period. A list of D-Link offices is provided at the back of this manual, together with a copy of the Registration Card. If a Registration Card for the product in question has not been returned to a D-Link office, then a proof of purchase (such as a copy of the dated purchase invoice) must be provided when requesting warranty service.
Limitation of Warranties IF THE D-LINK PRODUCT DOES NOT OPERATE AS WARRANTED ABOVE, THE CUSTOMER'S SOLE REMEDY SHALL BE, AT D-LINK'S OPTION, REPAIR OR REPLACEMENT. THE FOREGOING WARRANTIES AND REMEDIES ARE EXCLUSIVE AND ARE IN LIEU OF ALL OTHER WARRANTIES, EXPRESSED OR IMPLIED, EITHER IN FACT OR BY OPERATION OF LAW, STATUTORY OR OTHERWISE, INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.
Wichtige Sicherheitshinweise 1. Bitte lesen Sie sich diese Hinweise sorgfältig durch. 2. Heben Sie diese Anleitung fü r den spätern Gebrauch auf. 3. Vor jedem Reinigen ist das Gerät vom Stromnetz zu trennen. Vervenden Sie keine Flü ssigoder Aerosolreiniger. Am besten dient ein angefeuchtetes Tuch zur Reinigung. 4. Um eine Beschädigung des Gerätes zu vermeiden sollten Sie nur Zubehörteile verwenden, die vom Hersteller zugelassen sind. 5. Das Gerät is vor Feuchtigkeit zu schü tzen. 6.
Trademarks Copyright 1997 D-Link Corporation. Contents subject to change without prior notice. D-Link is a registered trademark of D-Link Corporation/D-Link Systems, Inc. All other trademarks belong to their respective proprietors. Copyright Statement No part of this publication may be reproduced in any form or by any means or used to make any derivative such as translation, transformation, or adaptation without permission from D-Link Corporation/D-Link Systems Inc.
T ABLE OF C ONTENTS 0 ABOUT THIS GUIDE ............................................................................... 2 1 INTRODUCTION ...................................................................................... 3 PRODUCT CAPABILITIES ................................................................................ 3 EXTERNAL FEATURES ................................................................................... 4 Front .........................................................................
DP-301P Print Server Hardware Guide 0 A BOUT THIS G UIDE This guide describes the D-Link DP-301P Multiprotocol Ethernet/Fast Ethernet Print Server. DP-301P features, installation procedures, and troubleshooting methods are explained in detail. The software and related documentation included with your DP-301P are important parts of the DP-301P package. For information on installing and using the included software, see the PS Admin User’s Guide.
DP-301P Print Server Hardware Guide 1 1 I NTRODUCTION The DP-301P is a pocket-sized device for connecting a printer directly to an Ethernet or Fast Ethernet local-area network (LAN). The DP-301P will manage the flow of data from networked computers to the connected printer, delivering jobs to the printer much faster than a computer acting as a file server or print server can.
DP-301P Print Server Hardware Guide because the DP-301P connects to your file servers through the network, the printer can be stationed at the location of maximum convenience to users. The DP-301P offers extraordinary flexibility, and works with all major network operating systems and protocols: ♦ IPX/SPX Novell NetWare 3.x and 4.
DP-301P Print Server Hardware Guide Front The panel on which the DP-301P’s network port, DC power jack, and light-emitting diode (LED) indicators appear is referred to in this guide as the device’s “front” section.
DP-301P Print Server Hardware Guide Indicators The DP-301P’s front panel includes three indicator lights. See "Power-up and Self-Test," Chapter 2, for a description of indicator behavior upon device startup. During operation following a normal startup, the indicators provide the following status signals: ♦ Pw/Tx Steady or flashing green confirms power on. This indicator blinks (goes off briefly) when the DP-301P is transmitting to the network.
DP-301P Print Server Hardware Guide Printer Port The printer port can be configured using the PS Admin program, or by commands issued to the DP-301P via Telnet. See the PS Admin User’s Guide for configuration procedures.
2 2 U NPACKING AND I NSTALLATION This chapter explains how to install your DP-301P print server and connect it to the network. It also describes the automatic power-on self-test. Unpacking and Inspection Carefully remove all items from the package.
DP-301P Print Server Hardware Guide Installing the DP-301P Follow these steps for a trouble-free start of print-server operations with your DP-301P. Please take particular notice of the warning in step 4: the network connection should be made before supplying power to the DP-301P. 1. Confirm proper operation of the printer to be connected to the DP-301P. 2. When you have confirmed proper operation of the printer, switch its power off. 3. Confirm that your network is operating normally. 4.
DP-301P Print Server Hardware Guide Power-up and Self-test Whenever the DP-301P is powered up, two testing procedures follow automatically. The first procedure is a programmed series of flashes intended to confirm proper operation of the three LED indicators. The second procedure comprises programmed tests of the DP-301P’s internal circuitry. If any fault is found during the circuitry tests, testing stops and a continuous pattern of flashes signals the nature of the fault.
DP-301P Print Server Hardware Guide LPT Indicator Flash Pattern Error Type steady long flashes Firmware Reload Required continuously on DRAM Error One long, two short flashes Timer INT Error One long, three short flashes Flash Protected One long, four short flashes Flash ID Error One long, five short flashes Flash Erase / Program Error One long, six short flashes LAN Controller Error One long, seven short flashes LAN Memory Error One long, eight short flashes Parallel Controller Error O
DP-301P Print Server Hardware Guide A 3 P RODUCT S PECIFICATIONS Printer Connection Printer Port: IEEE 1284 standard bidirectional parallel interface with 36-pin connector. Bidirectional Communication: Hewlett-Packard PJL (Printer Job Language) standard for bidirectional communication. Network Connection Network Standards: IEEE 802.3 10Base-T Ethernet and IEEE 802.3u 100Base-TX Fast Ethernet.
DP-301P Print Server Hardware Guide TCP/IP Protocols Supported: BOOTP, SNMP, Telnet, TFTP, FTP, lpd, RARP, DHCP Management and Diagnostics Standard: SNMP MIBs: MIB-II (RFC 1213) Diagnostic LED Indicators: Pw/Tx, Lk/Rx, LPT Environmental and Physical Power Supply: External AC power adapter providing 5V/1.5A DC power Dimensions: 92.8mm × 58mm × 25.3mm Weight: approx.
B 4 P ORT P INOUTS The following table lists the pinouts of the DP-301P’s 36-pin parallel port connector (identical to the parallel port connector used on most printers.) Signal names beginning with n are active-low signals. Pin # 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 ♣ Signal nStrobe Data 1 ♣ Data 2 Data 3 Data 4 Data 5 Data 6 Data 7 Data 8♦ nAck Busy PError Select nAutoFd Not Defined Logic Gnd Chassis Gnd Least Significant Bit Data signals will be driven by some , but not all peripheral devices.
DP-301P Print Server Hardware Guide 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 Port Pinouts Peripheral Logic High Signal Ground (nStrobe) Signal Ground (Data 1) Signal Ground (Data 2) Signal Ground (Data 3) Signal Ground (Data 4) Signal Ground (Data 5) Signal Ground (Data 6) Signal Ground (Data 7) Signal Ground (Data 8) Signal Ground (PError, Select, nAck) Signal Ground (Busy, nFault) Signal Ground (nAutoFd, nSelectIn, nInit) nInit nFault Not Defined Not Defined Not Defined nSelectIn P H
5 I NDEX 100Base-TX, 5, 12 10Base-T, 5, 12 AC power adapter, 5, 8, 9, 13 AppleTalk, 4, 12 automatic self test, 8 bidirectional printer port, 3, 12 cable, 5 DC power, 5, 9, 13 diskettes, 8 EtherTalk, 4, 12 file server, 3, 4 firmware, 11 IEEE 1284, 3, 12 IEEE 802.3, 12 IEEE 802.
Offices U.S.A. CANADA D-LINK SYSTEMS, INC. 53 Discovery Drive, Irvine, CA 92618 USA TEL: 1-714-788-0805 FAX: 1-714-753-7033 WEB: www.dlink.com BBS: 1-714-455-1779 E-MAIL: tech@dlink.com D-LINK CANADA, INC. 6 - 2180 Dunwin Drive, Mississauga, Ontario, Canada , L5L 5M8 TEL: 905-828-0260 ; 905-828-5074 . FAX: 905-828-5669 WEB: www.dlink.ca BBS: 905-828-6673 E-MAIL: support@dlink.ca sales@dlink.ca FTP: ftp.dlinknet.com DENMARK D-LINK DENMARK FRANCE D-LINK FRANCE GERMANY D-LINK (DEUTSCHLAND) GMBH I.G.
Registration Card Print, type or use block letters. Your name: Mr./Ms_____________________________________________________________________________ Organization: ________________________________________________ Dept.