Setup guide

call, or want to receive calls from, i.e., (the IP telephone 10.0.0.224 and the Welltech IP
telephone 10.5.8.2):
[admin@voip_gw] ip telephony voice-port voip> add name=joe \
\... remote-address=10.0.0.224
[admin@voip_gw] ip telephony voice-port voip> add name=rob \
\... remote-address=10.5.8.2 prefered-codec=G.723.1-6.3k/hw
[admin@voip_gw] ip telephony voice-port voip> print
Flags: X - disabled, D - dynamic, R - registered
# NAME AUTODIAL REMOTE-ADDRESS JITTER-BUFFER PREFERED-CODEC SIL FAS
0 joe 10.0.0.224 100ms none no yes
1 rob 10.5.8.2 100ms G.723.1-6.3k/hw no yes
[admin@voip_gw] ip telephony voice-port voip>
• Add number records to the /ip telephony numbers, so you are able to make calls:
[admin@voip_gw] ip telephony numbers> add dst-pattern=31 voice-port=rob prefix=31
[admin@voip_gw] ip telephony numbers> add dst-pattern=33 voice-port=joe prefix=33
[admin@voip_gw] ip telephony numbers> add dst-pattern=1. voice-port=linejack1 \
\... prefix=1
[admin@voip_gw] ip telephony numbers> print
Flags: I - invalid, X - disabled, D - dynamic, R - registered
# DST-PATTERN VOICE-PORT PREFIX
0 31 rob 31
1 33 joe 33
2 1. linejack1 1
[admin@voip_gw] ip telephony numbers>
Making calls through the IP telephony gateway:
• To dial the IP telephone 10.0.0.224 from the office PBX line, the extension number 19 should
be dialed, and, after the dial tone has been received, the number 33 should be entered. Thus,
the telephone [Joe] is ringed.
After establishing the voice connection with '33' (the call has been answered), the voice port
monitor shows:
[admin@voip_gw] ip telephony voice-port linejack> monitor linejack1 status:
connection port: line direction: port-to-ip line-status: plugged phone-number: 33
remote-party-name: linejack1 [10.0.0.224] codec: G.723.1-6.3k/hw duration: 1m46s
[admin@voip_gw] ip telephony voice-port linejack>
• To dial the IP telephone 10.5.8.2 from the office PBX line, the extension number 19 should be
dialed, and, after the dial tone has been received, the number 31 should be entered.
Setting up the Welltech IP Telephone
Please follow the documentation from www.welltech.com.tw on how to set up the Welltech LAN
Phone 101. Here we give just brief recommendations:
1. We recommend to upgrade the Welltech LAN Phone 101 with the latest application software.
Telnet to the phone and check what you have, for example:
usr/config$ rom -print
Download Method : TFTP
Server Address : 10.5.8.1
Hardware Ver. : 4.0
Boot Rom : nblp-boot.102a
Application Rom : wtlp.108h
DSP App : 48302ce3.127
DSP Kernel : 48302ck.127
DSP Test Code : 483cbit.bin
Ringback Tone : wg-ringbacktone.100
Hold Tone : wg-holdtone10s.100
Ringing Tone1 : ringlow.bin
Ringing Tone2 : ringmid.bin
Ringing Tone3 : ringhi.bin
usr/config$