User's Manual

interface, UART communication is the default mode of communication with
the host.
4.5 USB port
Pin 3 (USB-M), Pin 4 (USB-P) and Pin 12 (USB +5V) provide connection to
a USB host at full speed. USB +5V line is used to detect the USB host and
does not consume power.
4.6 Installation of software
4.6.1 Application software package
The application software consists of several dlls and applications.
These are rfidhost.inv.exe, rfidhost.test.exe, cpl.dll, rfidtx.dll, rfid.dll and
profiler.dll. Also USB device driver is included
4.6.2 Installing the USB Communication-Bus Driver on Windows XP
The RFID Radio Module is a USB Plug-and-Play device. Installation of the
driver on Windows XP is a simple procedure:
1. Plug the RFID Radio Module into a USB port on the machine where you
have installed the application software.
2. When asked to specify additional locations to search for driver software,
enter APP_DIR\USB.Driver.
3. When shown a list of devices to select, select the device labeled:
UsbHarve.Sys for Intel Harve RFID MAC
4. This driver has not been signed by Microsoft; When asked, continue with
installation of the unsigned driver