The POWER In PRESENTATION PRODUCTS DA-LITE SCREEN COMPANY, INC. Instruction Book for DESIGNER CONTOUR® ELECTROL® 3100 North Detroit Street Post Office Box 137 Warsaw, Indiana 46581-0137 Phone: 574-267-8101 800-622-3737 Fax: 574-267-7804 Toll Free Fax: 877-325-4832 www.da-lite.com e-mail: info@da-lite.
IMPORTANT SAFETY INSTRUCTIONS When using your video equipment, basic safety precautions should always be followed, including the following: 1. Read and understand all instructions before using. 2. Position the cord so that it will not be tripped over, pulled, or contact hot surfaces. 3. If an extension cord is necessary, a cord with a current rating at least equal to that of the appliance should be used. Cords rated for less amperage than the appliance may overheat. 4.
INSTALLATION Carefully unpack screen and remove outer wrapping from case. 4-1/4" Remove the black tape from the slat bar after the case has been installed. CASE HOOK There are three ways to install the Designer Contour Electrol: Wall Mount, Ceiling Mount, or Ceiling Hook. Procedures for each method are as follows: 5/16" 9/16" Wall Mount 1. Secure the wall mount bracket to the wall at the desired height. Bracket should be fastened to wall studs or some reinforcement within the wall.
ELECTRICAL INSTALLATION Internal wiring has been completed at the factory. Installer must route power to the wall switch and to the junction box located on the left end of the screen case. Standard installation is for a single 120VAC or 240VAC wall switch to control the screen. Optional Control units may have been ordered. Wiring diagrams for the built-in VPI and low voltage control are included in these instructions.
ELECTRICAL INSTALLATION 120V WIRING DIAGRAM WITH OPTIONAL BUILT-IN LOW VOLTAGE CONTROL RED BLACK MOTOR WHITE (COMMON) EYE AUX GROUND TO CASE BLACK WHITE RED UP STOP DOWN 120VAC 60HZ WHITE (COMMON) LOW-VOLTAGE WALL SWITCH BLACK (HOT) OPTIONAL RF OR IR REMOTE CONNECTOR GREEN GROUND–MUST BE CONNECTED TO BUILDING GROUND 240V WIRING DIAGRAM WITH OPTIONAL BUILT-IN LOW VOLTAGE CONTROL BLACK (UP) BROWN (DOWN) MOTOR OPTIONAL RF OR IR REMOTE CONNECTOR BLUE (COMMON) BLACK AUX EYE GROUND TO CASE
SCREEN ADJUSTMENT Screen travel is stopped automatically in the down and up positions by the limit switches that are preset at the factory. If it’s necessary to adjust for more or less drop follow the steps below. The case cover must be removed to access the motor limit switches. Remove the case cover screw from both ends of the screen. See figure 4. Be sure to hold the cover while removing the screws. Rotate the cover up and away from the case until it can be removed.
TROUBLESHOOTING SYMPTOM 1. Screen will not operate. Motor does not hum. CAUSE SOLUTION (a) Incorrect line voltage. (a) Verify 115-125V (or 220-240V). If insufficient voltage, rewire incoming electric line. (b) Replace fuse. (c) Reset circuit breaker. (d) Check above. Tighten all loose wire connections. Correct any improper connections. “Down” Position Check for power across black and white leads. “Up” Position Check for power across red and white leads. (b) Blown fuse. (c) Tripped circuit breaker.
Printed in U.S.A. 89697 Rev.