Installation instructions
7
RJ45
Receptacle
RJ22
Output
RJ22
Inputs
Up (Dry Contact)
Down (Dry Contact)
Common (Both)
Bus (Bus)
5V (Bus)
UP
STOP
DOWN
BUS
COM
5V
Front of
Wall Switch
Bus
UP
STOP
DOWN
BUS
COM
5V
Led
Up Limit
Tactile Button
Down Limit
Tactile Button
Back of
Wall Switch
UP
STOP
DOWN
BUS
COM
5V
Power Input 120VAC / 60Hz
Green (Ground)
(Ground–Must be Connected
to Building Ground)
Black
(Hot)
White
(Common)
Power
Wire
Data
Cable
RJ45 Jack
RJ22 Jack
(Connection to
Wall Switch)
RJ22
Jack
Tensioned Contour
®
Electrol
®
Installation for 120V Screens
5/12 Volt
Screen Trigger
on Projector
Black
Red
VPI Trigger
Module
120V Wiring Diagram with Optional Built-In Video Projector Interface
CAUTION: The projector must be turned of before
connecting the trigger wires to the projector. Failure to
do so may damage the controller.
ATTENTION: Le projecteur doit être éteint avant de
brancher les ils de déclenchement à celui-ci. Tout
manquement à cette instruction pourrait endommager
le contrôleur.
Use 2-conductor 1824 gauge wire to extend the low voltage
connection from the projector’s 5 or 12-volt screen trigger output
to the length required to reach the VPI. When extending the low
voltage connection from the projector’s screen trigger output
polarity does not matter. The red and black wires from the VPI
are interchangeable.
IMPORTANT NOTE: The wall switch is REQUIRED to make any
limit switch adjustments, EVEN if a third party control system is
used. Therefore, it is advised to wire the switch or provide a
3-conductor connection that is accessible.
3-conductor 2024 gauge wire can be used in place of the
supplied RJ14 cable to connect the wall switch. Connect the BUS
terminals on the wall switch to the corresponding BUS terminals
on the splitter board.