Repair Manual

STARTING AND CHARGING
16
16 - 16
R
EMOUNTING
Check the new diode.
Press the new diode in the diode support observing the marking : red for “ + “ , black
for “ - “.
Mount the diode support on the alternator.
CHECKING OF THE RECTIFYING BRIDGE
After dismounting the diode support perform a visual checking of the diodes to avoid
defects ( short circuits, broken ) as well as the connections state.
A. CHECKING OF THE POSITIVE DIODES
Place the red terminal ( positive cable )
of the ohmmeter on the support , in “ d “
point then the black terminal ( negative
cable ) in sequence in “ a point , “ b
point and “ c “ point. After reversing the
cables and repeating the checking the
ohmmeter needle must not deviate
( resistance = ).
B. CHECKING OF THE NEGATIVE DIODES
Place the negative terminal of the ohmmeter on the support, then on “e” point,after
that, the red terminal in sequence ,on “a” point , “ b” point and on “c “ point.
For a correct operation, the ohmmeter needle must deviate. After reversing the cables
and repeating the checking on the mentioned points , the ohmmeter needle must not
deviate ( resistance = ).
ALTERNATOR