Repair Manual
16
STARTING AND CHARGING
16 - 19
VOLTAGE REGULATOR
( alternator type 1114.200 )
D
ISMOUNTING
Disconnect: the battery, the ( + ) supply cable and the excitation wire of the voltage
regulator by unscrewing the fixing nut.
Unscrew the right side nut, loosen the left side one and dismount the relay.
R
EMOUNTING
Place in its place the regulator and tighten the fixing screws.
Connect :
- the supply cable;
- the excitation wire by tightening the nut;
- the battery.
ALTERNATOR
vnx.su