Product data
Base Grille Water Filtration System (Water Filter)
Model WF-LC400V/LC400V Capacity 400 Gallons (1514 Liters)
Tested and certified by NSF International against ANSI/NSF Standard 42 for
the reduction of Chlorine Taste and Odor, Particulate Class I*; and against
ANSI/NSF Standard 53 for the reduction of Lead, Mercury, Atrazine, Benzene,
Toxaphene, p-dichlorobenzene, 2, 4-D, Cysts, Turbidity and Asbestos.
This system has been tested according to ANSI/NSF 42/53 for the reduction of the substances listed below. The concentration of the
indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for water
leaving the system, as specified in ANSI/NSF 42/53.
Substance Reduction NSF Reduction Average Influent Challenge Maximum Average Minimum % Average %
Aesthetic Effects Requirements Influent Concentration Effluent Effluent Reduction Reduction
Chlorine Taste/Odor >50% 2.1 mg/L 2.0 mg/L + 10% 0.06 mg/L 0.05 mg/L 97.1% 97.6%
Particulate Class 1" >85% 5,366,667/mL At least 10,000 4,100/mL** 2,300/mL 99.3% 99.9%
particles/mL
NSF Reduction Average Influent Challenge Maximum Average Minimum % Average %
Requirements Influent Concentration Effluent Effluent Reduction Reduction
0.01mg/L 0.152 mg/L1- 0.15 mg/L + 10% 0.001 mg/L 0.001 mg/L 99.34% 99.34%
0.01mg/L 0.143 mg/L1- 0.15 mg/L + 10% 0.001 mg/L 0.001 mg/L 99.30% 99.30%
0.002 mg/L 0.0061 mg/L 0.006 mg/L + 10% 0.0004 mg/L 0.0003 mg/L 93.5% 96.7%
0.002 mg/L 0.0057 mg/L 0.0058 mg/L + 10% 0.0008 mg/L 0.00051 mg/L 85.8% 91.2%
0.005 mg/L 0.0162 mg/L 0.015 + 10% 0.0005 mg/L 0.001 mg/L 96.3% 96.3%
0.075 mg/L 0.220 mg/L 0.225 + 10% 0.0005 mg/L 0.0005 mg/L 99.7% 99.7%
0.003 mg/L 0.014 mg/L 0.015 + 10% 0.0014 mg/L 0.001 mg/L 90% 92.96%
0.003 mg/L 0.0086 mg/L 0.009 mg/L + 10% 0.0005 mg/L 0.0005 mg/L 94.25% 94.25%
0.07 mg/L 0.197 mg/L 0.210 + 10% 0.058 mg/L 0.0137 mg/L 70.6% 93.06%
99% 26 x 107 107 to 108 fibers/L1-1- 0.18 x 107 mg/L 0.18 x 107 mg/L 99.93% 99.93%
99.95% 111,000/mL 50,000/L min. 1 mg/L 1 mg/L 99.99% 99.99%
0.5 NTU 11.00 NTU 11 + 1 NTU 0.40 NTU 0.35 NTU 96.4% 96.8%
= 7.5 + 0.5 unless otherwise noted. Flow = 0.5 gpm (1.9 Lpm). Pressure = 60 psig (413.7 kPa). Temp. = 63°F
Contaminant
Reduction
Lead: @ pH 6.5
Lead: @ pH 8.5
Mercury: @ pH 6.5
Mercury: @ pH 8.5
Benzene
p-dichlorobenzene
Toxaphene
Atrazine
2, 4-D
Asbestos
Cysts:):
Turbidity
Test Parameters: pH
(17.2°C).
It is essential that operational, maintenance, and filter
replacement requirements be carried out for the product to
perform as advertised.
• The filter monitor system measures the amount of water that
passes through the filter and alerts you to replace the filter.
When 90% of the filter's rated life is used, the filter indicator
light changes from green to yellow. When 100% of the filter's
rated life is used, the filter indicator light changes from yellow
to red, and it is recommended that you replace the filter. Use
replacement cartridge AFF5. See www.everythingdacor.com.
• The product is for cold water use only.
Application Guidelines/Water Supply Parameters
Water Supply City or Well
Water Pressure 30 - 120 psi (207 - 827 kPa)
Water Temperature 33 ° - 100°F (0.6 ° - 37.8°C)
Service Flow Rate 0.5 GPM (1.89 L/min.) @ 60 psi.
* Class I particle size: >0.5 to <1 um
** Test requirement is at least 100,000 partictes/mL of AC Fine Test Dust.
1 These contaminants are not necessarily in your water supply. Performance may vary based on local water conditions.
1"1"Fibers greater than 10 um in length
:1:Based on the use of Cryptosporidium parvum oocysts
® NSF is a registered trademark of NSF International.
18