Installation Instructions

2
View data plate
through grate
Model Identification
Callout
Name Description
A Model series (HWO) Heritage Wall Oven
B Number of ovens 1 (single oven) or 2 (double oven)
C Width Inches (overall exterior)
D Handle style F: flush; P: Pro; No designator: Epicure
E Color/Material B: Black; S: Stainless steel; W: White
F Voltage 208V: 208 Vac; No designator: 240 Vac
If you have questions or installation/repair/warranty issues, call:
Dacor Customer Assurance
Phone: 833-35-ELITE (833-353-5483) USA, Canada
Mon – Fri 5:00 a.m. to 5:00 p.m. Pacific Time
Website: www.dacor.com/customer-care/contact-us
Product Data Label
When you call for assistance, have the oven’s model and serial
numbers ready. These numbers are on the product-data label
behind the grill above the oven chamber. On double ovens, the
label is behind the upper oven’s grill.
The owner shall ensure that a licensed electrician installs the oven’s electrical supply (incl. minimum supply wire size), which must
comply with the Nat’l Electric Code ANSI/NFPA 70 (latest rev.) and local codes/ordinances.
Obtain a copy of this standard from:
National Fire Protection Association
1 Batterymarch Park
Quincy, MA 02269-9101
Correct voltage/frequency/amperage must be sup-
plied to the oven from a dedicated, grounded, single-
phase circuit protected by a properly sized circuit
breaker or time-delay fuse. (For the fuse, fuse both
sides of the line: L1 and L2.)
Preheat times and cavity temperature-recovery
times increase slightly if operating a 240 Vac unit
with less than a 240 Vac circuit.
The oven has electrical wiring in a flexible metal
conduit.
CUSTOMER ASSURANCE INFORMATION
ELECTRICAL SPECIFICATIONS
Model Total Connected Load*
Dedicated Circuit
Requirements
HWO127 240 Vac 60 Hz, 19.0 Amp., 4.7 kW
240 Vac 60 Hz, 4 wire**, 30 Amp.
HWO130 240 Vac 60 Hz, 24.5 Amp., 6.0 kW
HWO227 240 Vac 60 Hz, 39.4 Amp., 9.5 kW 240 Vac 60 Hz, 4 wire**, 40 Amp.
HWO230 240 Vac 60 Hz, 48.6 Amp., 12.0 kW 240 Vac 60 Hz, 4 wire**, 50 Amp.
*For reference only. See the product data label (pg. 2) for exact specifications; **two 120