Installation Instructions

10
Installation Instructions
Verifying the Correct Setup
WARNING
Make sure that power to the electrical outlet is turned
off at the circuit breaker panel or fuse box and that
the gas is turned off at the gas supply valve before
proceeding.
The cooktop must be properly grounded at all times
when electrical power is applied.
Prior to operating the cooktop, read the accompanying Use
and Care Manual carefully.
1. Make sure all the cooktop burner controls are in the
OFF position.
2. Connect the power cord to the electrical outlet.
3. Turn on power to the electrical outlet at the circuit
breaker or fuse box.
4. Press and turn ONE burner control knob slowly left to
the HIGH position. Verify that the associated burner
igniter sparks, then return the knob to the OFF position.
Repeat for all of the remaining control knobs.
5. Turn gas supply valve ON.
6. Perform this IGNITION TEST on all burners:
Press and turn the control knob slowly left to the
HIGH position. Only the selected burner will spark.
It may take up to four seconds for the burner to
ignite, at which time the igniter will stop sparking.
If ignition does not occur within four seconds, turn
the knob OFF, wait for at least five minutes to allow
any gas to dissipate, then repeat this step.
Once the burner lights, rotate the control knob
from HIGH toward LOW to adjust the flame height.
SimmerSear™ burners: turn the control knob to
the simmer setting, and make sure the low-level
flame can be adjusted.
When the unit is installed correctly, the flame will
burn steadily. It will have a sharp, blue inner cone
that will vary in length proportional to the burner
size. The flame will be reduced by the Smart
Flame™ feature under the grate fingers to increase
the life of the grate.
Single Burner
Control Knob
Correct Flame Appearance
Flame
Low
NOTE: If the cooktop does not function properly, follow
these troubleshooting steps:
Verify that power and gas are supplied to the cooktop.
Check to make sure that the power cord is connected
to an electrical outlet and that power is turned on at the
circuit breaker, fuse box, or light switch.
Check to make sure that all the burners are correctly
assembled and seated.
If the burner continues sparking after ignition, have a
licensed electrician check the electrical outlet for cor-
rect grounding or reversed polarity.
Repeat the IGNITION TEST (Step 6).
If the appliance still does not work, contact Dacor
Distinctive Service at (800) 793-0093, ex. 2822. Do not
attempt to repair the appliance yourself. If you need
service, be sure to have the model and serial numbers
available when you call. See inside cover for location.
Dacor is not responsible for the cost of correcting problems
caused by a faulty installation.
SimmerSear
Control Knob
Flame
Low
High
Low
Simmer
OFF
Burner
Indicator
Burner
Light
Flame
High
On
Simmer
OFF
Burner
Indicator
Burner
Light
Flame
High
On