Installation Instructions Distinctive ™ 30 Inch Wide Electric Range Models: DR30ES, DR30ES-C, DR30EFS, DR30EFS-C, DR30EIS and DR30EIFS Part No. 105906 Rev.
Table of Contents Important Safety Instructions...................................................... 1 Important Information About Safety Instructions......................... 1 Safety Symbols in this Manual....................................................1 General Safety Precautions......................................................... 2 Product Specifications.................................................................3 Electrical Requirements (U.S.A.)...........................................
Important Safety Instructions Important Information About Safety Instructions The Important Safety Instructions and warnings in this manual are not meant to cover all possible problems and conditions that can occur. Use common sense and caution when installing, maintaining or operating this or any other appliance. Always contact the Dacor Customer Service Team about problems and conditions that you do not understand.
Important Safety Instructions General Safety Precautions To reduce the risk of fire, explosion, electric shock, serious injury or death when installing or using this appliance, follow basic safety precautions, including the following: warning • Read all instructions before using the appliance. • Keep packaging materials away from children. Plastic sheets and bags can cause suffocation. • If you receive a damaged product, immediately contact your dealer or builder.
Product Specifications warning IMPORTANT: Observe all governing codes and ordinances during planning and installation. Contact your local building department for further information. Electrical Requirements (Models DR30ES-C and DR30EFS-C) • Models DR30ES-C and DR30EFS-C are freestanding ranges that come with a factory installed 4-wire appliance cord and NEMA 14-50P plug.
Product Specifications Product Dimensions Product tolerances: ±1/16” (±1.6 mm), unless otherwise stated Front of open door Front of handle/knobs Front panel Rear of front panel A B C D 1” (2.5 cm) 9” (22.9 cm) Backguard* Backguard thickness 6” (15.2 cm) 3” (7.6 cm) backguard* backguard* DR30EI[F]S: 3/8” (9.5 mm) External handle shown, some models have integral handle (see inside cover) Product width: 29 15/16” (76.0 cm) DR30E[F]S: Full stainless steel side panels DR30EI[F]S: 3” (7.
Installation Specifications Cabinet Layout • warning • • • Observe all governing codes and ordinances during planning and installation. Contact your local building department for further information. • All minimum cabinet/counterop clearances shown on the following pages must be met or exceeded. • To eliminate the risk of burns or fire by reaching over heated surface units, cabinet storage space locate above surface units should be avoided.
Installation Specifications Self-Rimming Installation Cutout Options (Models DR30EIS and DR30EIFS Only) Countertop height: 34 3/4” (88.3 cm) min. 36 7/8” (93.7 cm) max. Countertop thickness: 1 5/8” (4.1 cm) max. • On self-rimming installations when sliding the range into position, it will stop when the rear of the control panel or side panels contact the notches toward the front of the countertop.
Installation Specifications Self-Rimming Installation with Raised Vent Cutout Options (Models DR30EIS and DR30EIFS Only) Countertop height: 34 3/4” (88.3 cm) min. 36 7/8” (93.7 cm) max. Countertop thickness: 1 5/8” (4.1 cm) max. • A self-rimming countertop configuration is required for raised vent installation. On installations with a raised vent, when sliding the range into position, it will stop when the rear of the control panel or side panels contact the notches toward the front of the countertop.
Installation Instructions Verify the Package Contents Verify that all the components below have been provided. If any item is missing or damaged, please contact your dealer immediately. Do not install a damaged or incomplete appliance. Make sure that you have everything necessary to ensure proper installation before proceeding. • • • • • Use and care manual Anti-tip bracket with screws and anchors Oven racks (2) Razor blade scraper Dacor Cooktop Cleaning Cream 1.
Installation Instructions To determine if the base plate is high enough: a. 4. Determine the location of the range center line and front panel when the range is in its final position based on the Product Dimensions on page 4 and the actual cabinet/cutout dimensions used for the installation. b. Determine and mark the required position of the anti-tip bracket, based on the diagram below. Push the bracket up against the wall in the mounting location. c.
Installation Instructions Backguard Installation Electrical Connection If installing a backguard or changing the factory installed backguard, install it before moving the range into position. Do not install a backguard if installing a raised vent. warning • Before proceeding, turn off power to the circuit to which the appliance will be connected at the circuit breaker or fuse box. • If the electric service provided does not meet the product specifications, do not proceed with the installation.
Installation Instructions Connecting Conduit to the Range NOTE: See page 14 for instructions to connect an appliance cord to the range. 1. Remove the range electrical access cover from the back of the range. 2. If using a 4-wire connection, loosen the grounding screw and remove the neutral to ground jumper link. 3. Remove the nut from the conduit strain relief (not included). 4. Slide the wires and the end of the strain relief into the hole on the bottom of the range electrical box.
Installation Instructions Electrical Connection (cont.) Connecting the Conduit to the House Electrical Junction Box warning • Do not connect the green appliance wire to the neutral (white) supply wire unless local building codes permit. • Do not ground the appliance to a gas supply pipe or hot water pipe. • A grounded cold water pipe must have metal continuity to electrical ground and must not be interrupted by insulating materials. Any insulating materials must be jumped with a length of No.
Installation Instructions Separate No.
Installation Instructions Electrical Connection (cont.) 5. Slide the end of the appliance cord into the strain relief from the bottom of the box. See facing page. Appliance Cord Connections - Where Local Code Permits 6. Connect the white (neutral) wire to the neutral terminal in the box. 7. Connect the L1 wire to the L1 power supply terminal in the box. 8. Connect the L2 wire to the L2 power supply terminal in the box. 9.
Installation Instructions L2 L1 Neutral Neutral L2 3-Wire Appliance Cord Plug L1 terminal Neutral terminal L2 terminal Ground L1 4-Wire Appliance Cord Plug L1 terminal Neutral terminal L2 terminal Jumper link Link removed Ground screw L1 wire White wire L2 wire L2 wire Green wire White wire L1 wire Strain relief 3-Wire Appliance Cord Connection Where Local Codes Permit Strain relief 4-Wire Appliance Cord Connection Where Local Codes Permit 15
Installation Instructions Installing the Range Re-installing the Oven Door Peel off the protective layer of plastic that covers the stainless steel surfaces. Freestanding Installation 1. Measure from the floor to the countertop and adjust the leveling legs as required to position the top frame at the desired height, based on the cabinet and countertop installation. 2. Carefully slide the range into position in the cutout. As you slide the unit into place the rear leg should engage the antitip bracket.
Installation Instructions Verifying Proper Operation 9. If either the oven or cooktop does not operate properly, follow these troubleshooting steps: 1. Remove any packaging from inside the oven. ◊ Verify that power is being supplied to the range. 2. Slide the oven racks onto the supports inside the oven chamber(s) according to the use and care manual. ◊ Check the electrical connections to ensure that the installation has been completed correctly. 3.
Dacor ● 14425 Clark Avenue, City of Industry, CA 91745 ● Phone: (800) 793-0093 ● Fax: (626) 403-3130 ● www.dacor.