Installation Manual

English 23
Installation requirements
Electrical Connection
For proper installation, you must determine th
e type of electrical connection you will
use and follow the directions in this manual.
The oven must be connected to the proper electrical voltage and frequency as given
on the model/serial/rating plate, which is on the bottom-left door trim.
Model/serial/
rating plate
Single Oven Double Oven
A circuit breaker is recommended.
Use this chart to determine the minimum recommended dedicated circuit protection.
KW Rating (240 V) KW Rating (208 V)
Recommended Circuit Size
(Dedicated)
≤4.8 KW ≤4.1 KW 20 Amp
4.9 KW - 7.5 KW 4.3 KW - 6.2 KW 30 Amp
7.3 KW - 9.6 KW 6.3 KW - 8.3 KW 40 Amp
9.7 KW - 12.0 KW 8.4 KW - 10.4 KW 50 Amp
Connect directly to the circuit-breaker box (or fused disconnect) through flexible,
armored- or nonmetallic-sheathed, copper cable with ground wire. (See Electrical
Connection.
Model/serial/
rating plate