Installation Guide

English 7
Preparation
Combination - oven Installed in Cabinet (Flush)
01 Dimensions provide minimum reveals. (except electrical supply location ‘E’)
02 Allow a minimum of 22’’ for clearance to adjacent corners, drawers, walls, etc.
when door is open.
03 Need a minimum of 1” for clearance below oven and top of cabinet or drawer.
04 Make sure there is no obstruction with minimum 2.5” clearance below ovens.
Top view
24
7
8
(630 mm)
1
3
8” (33 mm)
Side view Front view
Min. 40”
(1016 mm)
30
1
4” (767 mm)
Inside cleats
dimension
3
/4” (19.05 mm)
Max. 9
1
2
(241 mm)
43 ¾”
(1111 mm)
12”
(305 mm)
28
3
/4
(730.25 mm)
If codes permit and a separate ground wire is used, it is recommended that a
qualied electrical installer determine that the ground path and the wire gauge are
in accordance with local codes.
Check with a qualied electrician if you are not sure the oven is properly
grounded.
This oven must be connected to a grounded-metal permanent wiring system.
Be sure that the electrical connection and wire size are adequate and in
conformance with the National Electrical Code, ANSI/NFPA 70-latest edition or CSA
Standards C22.
1-94, Canadian Electrical Code, Part 1 and C22.2 No. O-M91-latest edition, and all
local codes and ordinances.
A copy of the above code standards can be obtained from:
National Fire Protection Association
1 Batterymarch Park
Quincy, MA 02169-7471
CSA International
8501 East Pleasant Valley Road
Cleveland, OH 44131-5575
Install_DOC30P977D_DG68-01317A-00_EN+MES+CFR.indb 7 2020-06-30 �� 4:51:34