Installation requirements
Installation requirements
Cabinet dimensions
All maximum and minimum dimensions and clearances shown in the diagrams below
must be maintained for safe operation.
Verify that the range installation site is away from any type of draft.
To reduce risk of fire and personal injury, cabinets should not be installed above the
range. If such cabinets are unavoidable, install a range hood that projects 5" beyond
the front of those cabinets.
CUTOUT DIMENSIONS
Range Model A B
DOP36M96*
42” (106.7 cm)*
36” (91.4 cm)**
36” (91.4 cm)**
36 1/8” (91.7 cm)***
* Recommended ** Minimum *** Maximum
Standard Cutout with Range Hood
A
B
13” (33.0 cm)
max.
5
Non-combustible
surface along back wall
recommended
Top of
finished
counter
10” (25.4 cm) min.
to combustible side
walls above the range
(both sides)
Suggested
location of
utilities
3
Grate
level
Note 2
18” (45.7 cm)
4, 5
30” (76.2 cm)
min.
1
37 1/2”
(95.3 cm)
max.
1
Vertical from range grate
level to combustible overhead
surface; if installing an
overhead vent hood, also
check hood specifications for
minimum required clearances.
2
Cabinet/countertop depth
is at discretion of customer
but cabinet face MUST NOT
protrude further than rear
of front panel, see product
dimensions.
3
Consult local code for exact
location requirements.
4
Vertical from grate level to
combustible surface.
5
This specification does not
apply for cabinets more than
a horizontal distance of 10”
(25.4 cm) from the edge of the
range.