Installation Manual
Table Of Contents
- Before you begin
- Important safety information
- Gas range components
- Installation requirements
- Tools and materials
- Installation instructions
- Antes de comenzar
- Información importante de seguridad
- Lea todas las instrucciones antes de usar este electrodoméstico
- Símbolos usados en este manual
- California Proposición 65 Advertencia
- Mancomunidad de Massachusetts
- Seguridad general
- Seguridad contra incendios
- Seguridad del gas
- Seguridad de la electricidad y la conexión a tierra
- Seguridad de la instalación
- Seguridad de la ubicación
- Seguridad de la cubierta
- Seguridad del horno
- Seguridad durante la auto-limpieza del horno
- Componentes de la estufa a gas
- Requisitos de instalación
- Herramientas y materiales
- Instrucciones de instalación
- Avant de commencer
- Informations importantes relatives à la sécurité
- Lisez toutes les consignes de sécurité avant d'utiliser cet appareil
- Symboles utilisés dans ce manuel
- California Proposition 65 Avertissement
- Commonwealth du Massachusetts
- Sécurité générale
- Sécurité incendie
- Sécurité liée au gaz
- Sécurité électrique et mise à la terre
- Sécurité liée à l'installation
- Sécurité de l'emplacement
- Sécurité liée à la table de cuisson
- Sécurité liée au four
- Sécurité liée à l'auto-nettoyage du four
- Composants de la cuisinière à gaz
- Conditions d'installation
- Outils et matériel
- Consignes d'installation
12 English
Installation requirements
Installation requirements
13 in (33 cm)
Overhead
Cabinet Depth
0 in (0 cm)
22.6 in
(573.5 mm)
24 in
(61 cm) Lower
Cabinet Depth
6 in*
(15.2 cm)
6 in*
(15.2 cm)
37 ⁄ in
(953 mm)
36 in
(914 mm)
18 in
(45.7 cm)
30 in (76.2 cm)
30 in (76.2 cm)
0 in (0 cm)
Clearance Below
Cooking Top
and at Rear and
Sides of Range
48 in
(121.9 cm)
Minimum to
combustibles
(Installation
without a
hood)
* Side clearance above cooking surface to any objects, i.e., wall.
Installation requirements
Location requirements
Clearances and dimensions
NOTE
• For OTR over Gas Stove, please follow local GAS CODE.
• BEFORE YOU BEGIN to install this appliance, refer to the following information,
dimensions, and clearances. Do not locate the range where it may be subject
to strong drafts. Provide adequate clearances between the range and adjacent
combustible surfaces. These dimensions must be met for safe use of the range.
The location of the electrical outlet and gas piping may be adjusted to meet
the following dimensions and clearances.
• For installation in Canada, a free-standing range is not to be installed closer
than 4.7 in (12 cm) from any adjacent surface.
• Installations without a hood require 48" minimum to combustibles. A custom
hood installation with exposed horizontal combustible surfaces must have
an Auto-On feature. Refer to hood installation instructions for specic hood
clearances.
CAUTION
This range has been designed to comply with the maximum allowable wood
cabinet temperature of 194 °F (90 °C). Make sure the wall covering, countertops,
and cabinets around the range can withstand the heat (up to 194 °F [90 °C])
generated by the range. If not, discoloration, delamination, or melting may occur.
Install_DOP36P86DLS_DG68-01106E-00_EN+MES+CFR.indb 12 2020-07-01 오후 3:44:03