Installtion Manual
7English
Installation Safety
•  
•  Do not service/alter/replace the range or any part of it unless as instructed in this manual. All other service 
•  Remove all tape and packing material.
•  
•  Ensure the anti-tip device is properly installed (Pg. 20).
•  Due to the size and weight of the range, have two or more people move the range.
•  After unpacking the product, remove all accessories, taking care with heavy pieces.
•  Verify that no parts came loose during shipping.
•  
gas (natural or LP) you will use. For the range to use LP gas, the installer must replace all surface burner 
responsible for the gas conversion.
•  Installation of this range must conform with local codes or, in their absence , with the National Fuel Gas 
Code, ANSI Z223.1/NFPA.54, latest edition. In Canada, installation must conform with the current Natu-
ral Gas and Propane Installation Code, CAN/CGA-B149.1, or the current Propane Installation Code, CAN/
ANSI Z21.1/CSA 1.1, latest edition.
Location Safety
•  Install the range indoors away from weather/water/strong drafts.
•  If the range is near a window, do not hang paper blinds or long curtains that could be blown over/onto the 
range.
•  The range must be installed within easy reach of a grounded, 4-prong outlet.
•  Wall and cabinet coverings around the range must withstand heat up to 194 °F (90 °C).
•  -
leum) must withstand 180°F (82°C) without shrinking, warping, or discoloring. The range must be separat-
ed from carpeting by a sheet of ¼" plywood or similar insulator.
•  
thus ensuring safe operation.
•  Avoid cabinet storage above the range; otherwise, allow at least 30 in. (76.2 cm) from cooking surface to 
cabinet bottom; or install a range hood that projects outward at least 5 in. (12.7 cm) beyond the cabinetry.
Important Safety Instructions
Installation-Related Safety Instructions, cont.
ensure proper installation.