Installation Guide

5
All tolerances: +1/16” -0” unless otherwise noted.
Cabinet and Countertop Layout
WARNING
To reduce the risk of personal injury caused by
reaching over a hot appliance, avoid locating cabinet
storage space directly above the cooktop.
Failure to meet or exceed the maximum and mini-
mum dimensions/clearances stated in these instruc-
tions may result in a fire hazard.
Follow the countertop manufacturer’s instructions
regarding the minimum corner radius, use of heat
reflective tape, reinforcement of corners, etc.
Carefully check the location where the cooktop will be
installed. For best performance, the cooktop should be
placed away from drafts that may be caused by doors,
windows and heating and air conditioning outlets.
This appliance is to be used in conjunction with a suit-
able vent hood or approved Dacor downdraft.
CLEARANCE REQUIREMENTS
Model A: Minimum A: Recommended
DTCT304G 30 in (76.2 cm) 36 in (91.4 cm)
DTCT365G 36 in (91.4 cm) 42 in (106.7 cm)
DTCT466G 46 in (121.9 cm) 54 in (137.2 cm)
Installation Specifications
Underneath Clearance and Allowances
Allow a minimum 1/4 in (6 mm) clearance between
the bottom of the cooktop chassis and
all combustible surfaces, including the edges and
corners of drawers that sit below the cooktop.
Model
B: Minimum clearance for hold-down
brackets
DTCT304G 29 in (73.7 cm)
DTCT365G 35 1/4 in (89.5 cm)
DTCT466G 45 1/4 in (114.64 cm)
Allow clearance for hold-down brackets
The gas supply piping, gas shut-off valve, and the
electrical outlet must be placed so they do not interfere
with the cooktop when it is installed.
If installing another appliance in the cabinet below,
allow for the routing of gas and power behind it.
The installation must allow for the following:
Access to the gas shut-off valve and regulator after the
unit is installed.
That the 40-inch (101.6 cm) power cord must be able
to reach an electrical outlet, and that outlet must be
accessable when the cooktop is in place.
Access to the underside of the cooktop for service and
inspection purposes.
Clearance inside the cabinet to allow for proper hold-
down bracket installation.
For access to the underneath of the cooktop, a fixed
shelf should not be installed below the cooktop.
See the following pages for countertop cutout dimensions.
Downdraft Compatibility
If installing the cooktop with a downdraft, use only the
approved Dacor model numbers specified below:
Cooktop
Models:
Use with These Approved
Downdraft Models:
DTCT304G ERV3015, PRV30, RV30
DTCT365G ERV3615, PRV36, RV36
DTCT466G PRV46, RV46
13 in max.
3
(33.0 cm)
3
Not applicable for cabinets more than a horizontal distance of 6 in.
(15.2 cm) from edge of cooktop. Allow 7 1/2 in
(19.1 cm) from edge
of cutout.
A
See cutout
dimensions
15 in min.
1
,
3
(45.7 cm)
1 7/8 in min.
(4.8 cm)
Combustible
surface to rear
Combustible overhead
cabinets
30 in min.
1
,
2
(76.2 cm)
7 1/2 in (19.1 cm) min. to
combustible side wall,
above counter (on both sides)
2
If installing with an overhead vent hood, also check hood
specifications for minimum required clearances.
1
Measured from top of cooktop grate.
1/4” (6 mm)
min. clearance
to combustible
surfaces
B