Combined Configuration DYO Wall Oven_Microwave-In-A-Drawer_Warming Drawer

All specications subject to change without notice.
Phone: (800) 793-0093www.dacor.com
PLANNING
GUIDE
COMBINATION INSTALLATIONS
DYO Wall Oven/Microwave In-A-Drawer/
Warming Drawer
Document # PGCI-033
Revised 09/17/14 Page 1/1
NOTE:
1. 3/4” (1.9 cm) support platform (flush with cutout).
2. See individual appliance Planning Guide pages to
determine overlays.
3. Spacing between appliances and drawers/doors shown
is minimum required to allow for ventilation and prevent
scraping. Additional space may need to be added for
appearance.
CUTOUT DIMENSIONS
9 1/8”
(23.2 cm)
27 3/4”
(70.5 cm)
1 1/4” min.
(3.2 cm)
1 1/4” min.
(3.2 cm)
B
C
15 3/16”
(38.6 cm)
A
120 Vac electrical
outlet for microwave
240 Vac
wall oven
junction box
1
2” min. (5.1 cm)*
3/4” min.
(1.9 cm)
59 13/16”
(151.9 cm)
overall
stacked
height
120 Vac electrical outlet
for warming drawer
1
1
Wall Oven Models (A) Cutout Width
DYO130 28 1/2” (72.4 cm)
Warming Drawer
Models
(C) Cutout Width
30 inch 28 1/2” (72.4 cm)
Microwave
Model No.
(B) Cutout Width
MMD30(V) 28 1/2” (72.4 cm)
All tolerances: ±1/16” (±1.6 mm), unless otherwise stated.
WARNING
Observe all governing codes and ordinances during
planning and installation. Contact your local building
department for further information.
All appliances must be installed in accordance with the
accompanying installation instructions.
*3” (7.6 cm) Recommended